Thermal runaway (TR) in lithium-ion batteries represents a major safety challenge for electric vehicles, battery energy storage systems, and other electrified applications. This project evaluated technologies and methodologies for providing early warning of battery failure before or during the onset of TR. The work combined a comprehensive literature review with laboratory sensor evaluations, controlled battery cell abuse tests, and full-scale battery electric vehicle (BEV) fire tests. The literature review identified substantial variability in gas generation and failure characteristics as functions of cell chemistry, state of charge (SOC), trigger method, and environmental conditions. Volatile organic compounds (VOCs), electrolyte vapours, hydrogen, and carbon monoxide were identified as key detection targets, while electrochemical impedance spectroscopy (EIS) emerged as a promising technique for detecting internal degradation prior to gas release from the cell. Metrological evaluation of three gas-sensing technologies demonstrated that realistic battery off-gas mixtures strongly influence sensor performance. Furthermore, twenty-two large-format cell abuse tests showed that failure behaviour depends strongly on chemistry, SOC, and heating rate. Electrolyte vapours dominated early venting emissions and sensors designed for electrolyte vapours and VOC detection consistently alarmed earliest. EIS detected internal degradation 15–37 minutes before TR in slow-heating scenarios, outperforming gas-based methods. Full-scale BEV tests confirmed that battery-specific off-gas detectors can provide rapid warning in realistic fire scenarios and that sensor placement significantly affects response time. Overall, the results indicate that robust TR detection requires a multi-layered strategy combining battery diagnostics, sensitive off-gas detection, and conventional fire detection technologies to support effective battery safety management and emergency response efforts.
QC 20261104