Development of an optimised Fibre-Optic Sensor for Laboratory and Substation noninvasive Calibration of Current TransformersShow others and affiliations
2026 (English)In: CIGRE Science and Engineering, ISSN 2426-1335, Vol. 2026-June, no 41Article in journal (Refereed) Published
Abstract [en]
Accuracy of voltage and current measurements is a crucial aspect in power systems management, from grid control in high voltage transmission and distribution grids to power quality parameter evaluation, up to energy and metering market fairness. Substation installed instrument transformers are key elements of the high voltage and current measurement chain, so their errors and stability over time should be verified periodically by comparison with metrology grade reference sensors. However, this is a costly and time-consuming procedure, if the instrument transformer in-line verification entails the breaking of the power circuit due to the use of an invasive reference sensor. To face this issue, focused research activities are being developed within the 23IND01 Electrical Energy and Supply Reliability (ENSURE) research project. In the paper, the ENSURE initial activities are presented, with reference to the development of on-site calibration methods of high voltage substation current transformers (CTs). The focus is on the development of a wideband, non-invasive, all-fibre-optic sensor to be used first as a laboratory reference in the calibration of CTs. Sensor characterisation procedures for use in high voltage substations are also dealt with. The sensor target performance is 0.05% for the measurement of the current fundamental tone up to at least 1kA and less than 0.5% up to the 50th/60th harmonic tone. Starting from a proof-of-concept sensor previously developed, a reference wideband all-fibre-optic current sensor (FOCS) is under finalisation. The features of the FOCS are detailed in the paper and characterisation tests are defined to quantify the current sensor performances under substation realistic conditions. Based on the available documentation, data and experience, a list of influence quantities with their range of variation is identified, focusing on on-site measurement conditions. The analysis is performed considering both the reference FOCS and off-the-shelf non-invasive sensors. Finally, laboratory characterisation circuits are discussed, which reproduce ideal and realistic substation current sensor operating conditions, along with first examples of characterisation tests
Place, publisher, year, edition, pages
CIGRE , 2026. Vol. 2026-June, no 41
Keywords [en]
calibration, current transformer, electrical substation, fibre-optic sensor, High voltage, measurement uncertainty, metrology, on-site verification
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82917Scopus ID: 2-s2.0-105051521185OAI: oai:DiVA.org:ri-82917DiVA, id: diva2:2110598
Note
Funding text: The project (23IND01 ENSURE) has received funding from the European Partnership on Metrology, co-\u2030nanced from the European Union\u2019s Horizon Europe Research and Innovation Programme and by the Participating States. | Funding details: European Partnership on Metrology, EPM; European Union’s Horizon Europe Research and Innovation Programme; Participating States, (23IND01 ENSURE)
2026-10-152026-10-152026-10-15Bibliographically approved