EMC-PROVNING VID STATENS PROVNINGSANSTALT - STRÅLAD STÖRNING
1988 (Swedish)Report (Refereed)
Abstract [en]
This report describes the methods used and problems that arise when performing Electromagnetic Radiation Susceptibility tests. In particular, the improved test method used at the Swedish National Testing Institute is discussed. As a result of the ever increasing use of electronic systems, radiated susceptibility tests are becoming more and more important. Computers and other electronic devices are used to control many different functions in industry and other parts of our society. Some of these control systems work without supervision and malfunctions due to Electromagnetic Disturbances (EMD) could be disastrous. A number of standards, national as well as international, describes general methods for testing and sets limit values to be able to evaluate the type of equipment mentioned above. However, these standards are general in nature and leaves some questions regarding details of the test methods. The methods used when performing Radiated Susceptibility tests prescribe a well defined electrical field strength at the position where the equipment under test (EUT) is placed. Due to reflection and standing wave phenomena introduced when using a shield (to protect the surroundings) and the fact that both the EUT and field strength meter distorts the field, a method of controlling the electrical field strength at the EUT position is preferred. The improved test method used at the Swedish National Institute, and described in this report, solves this problem. First, a calibration is performed at the EUT position, using only the field strength meter and recording the output signals needed to achieve the prescribed electrical field strength. When the calibration is done, the EUT is placed at the test position and the test is carried out using the recorded output signals. The calibration, recording and test is performed using a computer. When using this method, the uncertainty in the field strength value at the EUT is less than +25%. A very high resolution of the discrete test points can be achieved.
Place, publisher, year, edition, pages
Borås: Statens Provningsanstalt (SP) , 1988. , p. 17
Series
SP Rapport, ISSN 0284-5172 ; 1988:16
Keywords [en]
Electromagnetic Compatibility, EMC, Electromagnetic Interference, EMI, Electromagnetic Disturbance, EMD, Radiated Susceptibility, Immunity of electromagnetic radiation, test method, improved test method
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82985ISBN: 91-7848-101-5 (print)OAI: oai:DiVA.org:ri-82985DiVA, id: diva2:2110372
Note
SP Rapport 1988:16
2026-10-142026-10-142026-10-14Bibliographically approved