MEASUREMENT OF ENVIRONMENTAL VIBRATIONS IN SIX BUILDINGS. A proposal for a Nordtest method of measurement of annoying vibrations has been tested in 6 different field cases. The method is based on the maximum rms-acceleration level, measured with time weighting S (1 second). The frequency range considered is 1 to 80 Hz. A frequency-weighting curve is specified in accordance with the whole body combined weighting defined in ISO/DIS 8041. Measurements according to the proposed method have been carried out in six different buildings. The source of vibration was heavy traffic such as trucks and railway traffic. The result of the measurements, the subjective sensation and the threshold of sensation according to ISO 2631 have been compared and the correlation was good. A simple solution to avoid annoying vibrations has not been found. There are too many factors that influence on the strength of the vibration in a building: the distance between the source and the building; the mass and speed of the vehicle; the roughness of the road surface; soiltype and water contents of the ground; the foundation, the stiffness and the resonances in the building. An additional important factor for the annoyance is the number of passing vehicles and the time of the day on which they are passing.
SP Rapport 1988:12