Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Machine Learning-Based High-Voltage Circuit Breaker Defect Classification Utilizing Savitzky–Golay Filter
Tallinn University of Technology, EE.
Tallinn University of Technology, EE.
Tallinn University of Technology, EE.
Tallinn University of Technology, EE.
Show others and affiliations
2025 (English)In: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 74, p. 1-9Article in journal (Refereed) Published
Abstract [en]

High Voltage Circuit Breakers (HVCBs) are critical components in power systems to maintain reliable operation. Accurate condition monitoring of HVCBs is vital to reduce maintenance costs and consequently to enhance grid reliability. However, achieving this with low-cost measurement devices, which often provide noisy signals, poses a significant challenge. In this paper, a novel defect classification framework for HVCBs is proposed that uses the Savitzky-Golay filter to preprocess the most common condition monitoring signal, which is the trip/close coil current. This filter is well-known for denoising while preserving critical signal features. Following signal preprocessing, a robust defect detection and classification methodology is introduced, combining time series similarity assessment techniques, such as Euclidean distance and dynamic time warping, with machine learning algorithms. Moreover, an experimental setup is designed to emulate the behavior of an HVCB’s coil mechanism. To further enhance model transparency, Shapley additive explanations analysis is applied, providing interpretability into feature contributions toward model decisions. The obtained results validate the effectiveness of the proposed hybrid approach, demonstrating its potential to provide a cost-effective, accurate, and reliable solution for HVCB condition monitoring.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE) , 2025. Vol. 74, p. 1-9
National Category
Signal Processing
Identifiers
URN: urn:nbn:se:ri:diva-82933DOI: 10.1109/tim.2025.3604980Scopus ID: 2-s2.0-105015171174OAI: oai:DiVA.org:ri-82933DiVA, id: diva2:2109866
Note

Funding text: Estonian Transmission System Operator Elering AS through the Project “Risk and Condition Based Asset Management in Future Power Systems” (award: 1.1-4/2021/644/LEEEE21116); Estonian Ministry of Education and Science (award: TemTa-134)

Available from: 2026-10-12 Created: 2026-10-12 Last updated: 2026-10-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Lindquist, Tommie
By organisation
Measurement Technology
In the same journal
IEEE Transactions on Instrumentation and Measurement
Signal Processing

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 15 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf