FIVE YEARS OF OUTDOOR EXPOSURE OF FLAT PLATE SOLAR COLLECTORS - Measurements and evaluation of the influence on the thermal performance. During 1980/81 the National Testing Institute of Sweden (NTI), evaluated most of the flat plate solar collectors available on the Swedish market, with regard to thermal efficiency, durability and reliability. After completion of laboratory tests, these collectors were mounted outdoors on a roof at NTI, facing south, tilted 45° and without cooling. The test site is located at latitude 57° north. After about 5 years of accelerated ageing under stagnation conditions, some of these have now been reevaluated, with respect to thermal efficiency and a supplementary visual examination. This has given us the unique opportunity of comparing the effect of stagnation on the thermal performance, by comparing the same complete collector, in new and aged condition. In this case we can eliminate the question of individual differences, due to fabrication tolerances. For this investigation only solar collectors consisting of components still in use were selected. The changes in thermal performance have been compared with earlier results of accelerated ageing tests at NTI, on different absorber materials. All collectors show changes in their thermal performance. In most cases we can observe small or modest changes, but surprisingly not always as a degeneration of the performance. For operating temperatures equal to the surroundings, all collectors show a decrease in efficiency, ranging from 1 %-units to 5 at most, and with a mean value of 3.6. For operating temperatures above this (Tm-Ta > 0), the change in ke-value (= FR·UL) is more scattered, from almost none to deterioration, but also small improvements have been noticed for collectors with selective absorber coatings. For most collectors and changes an encouraging consistency with absorptance (α) and emissivity (ε) measurements on aged absorber samples can be observed. The solar collectors have resisted these severe conditions very well. F-CHART calculations show no major decrease in the yearly performance.
SP RAPPORT 1988:08