Model scale tests with automatic sprinkler in a tunnel
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0002-9340-6768
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0002-6264-7307
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0001-7744-2390
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0001-9468-4586
Show others and affiliations
2019 (English)Report (Other academic)
Abstract [en]

A model scale test series in a 1:3 scale was performed in order to investigate the performance of a fully automatic sprinkler system in a road tunnel. The investigation was carried out in order to explore if there is a possibility to retrofit an automatic sprinkler system in an existing road tunnel south of Stockholm. The experiments were carried in a steel container type of tunnel with adjusted geometry in scale. The tests were carried out by using scaled HGV trailer cargo loaded with wood pallets and scaled passenger cars. In total 16 tests were carried out by varying the longitudinal air velocity, activation temperature of sprinkler, type of fuel and type of arrangement of the fuel. The activation of the sprinkler nozzles was simulated by using thermocouples that corresponded to a given thermal response index (RTI) of a sprinkler with a bulb or a link. The RTI value of the simulated thermal device corresponds to 35 m 1/2 s 1/2 in full scale. The tests show that the number of activated sprinklers is weakly dependent on the activation temperature and strongly on the water density (or water pressure for given nozzles). The influence of the longitudinal velocity on the system performance was found to be limited, for the tested velocity range and type of fuel arrangement and size.

Place, publisher, year, edition, pages
RISE Research Institutes of Sweden , 2019. , p. 59
Series
RISE Rapport ; 2019:88
Keywords [en]
tunnel fire, model scale, tunnel velocity, automatic sprinkler, activation
National Category
Other Civil Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82749ISBN: 978-91-89049-18-5 (print)OAI: oai:DiVA.org:ri-82749DiVA, id: diva2:2101505
Note

This work was supported by the Tunnel and Underground Safety Center (TUSC)

Available from: 2026-09-15 Created: 2026-09-15 Last updated: 2026-09-15Bibliographically approved

Open Access in DiVA

fulltext(6091 kB)22 downloads
File information
File name FULLTEXT01.pdfFile size 6091 kBChecksum SHA-512
eb29b257a90f9c4b713cf0510543309827c115f6a9dbf34883878abd619a195e117c74ff64927ca1b3f69283c1aaa4128d9e113102e4850a425fc01701631c1c
Type fulltextMimetype application/pdf

Authority records

Ingason, HaukurArvidson, MagnusLi, Ying ZhenJiang, LeiBlom, Joel

Search in DiVA

By author/editor
Ingason, HaukurArvidson, MagnusLi, Ying ZhenJiang, LeiBlom, Joel
By organisation
Fire and Safety
Other Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 22 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 5456 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf