Smoke control in a longitudinally ventilated tunnel with various blockage conditions was investigated experimentally. The aim was to understand the influence of blockage on critical velocity and babcklayering length. Another aim was to reproduce the Memorial tunnel fire tests. The results confirm that blockage ratio is a critical parameter when determining the critical velocity and backlayering length. The blockage shape, size and location in relation to the fire source all influence the values of critical velocity and backlayering length in relation to free flow conditions. The experiments presented are in scale 1 to 3.3 and represents a medium sized tunnel. The focus was on free flow conditions, blockage ratios of regular sizes and finally the replica of the blockage conditions during the full scale tests in the Memorial tunnel between 1993 and 1995. The influence of these blockages on the upstream side of the fire had larger effects than have been anticipated in earlier studies. Originally a blockage of 17% on the upstream side was considered but the present study show it is more likely to be about 30%. The critical velocity is increased by a factor of 1.45 instead of 1.2, as used in the original work.
This work was supported by the Tunnel and Underground Safety Center (TUSC)