RISE, on behalf of the Swedish Energy Agency’s Testlab, has developed and applied a method for dynamic testing of photovoltaic (PV) and battery systems in Swedish single-family houses. The background is the rapidly growing market for battery storage connected to PV systems, where the need for clear, comparable, and realistic information on system performance and benefits has increased. Existing test methods are largely based on static test points, which do not always reflect real-world operation. The main purpose of this report is therefore to develop and verify a standardized method that better describes system performance under realistic, dynamic conditions, and to provide a basis for consumer guidance, industry development, and policy work. The method consists of several steps. First, four typical use cases are defined based on Swedish detached houses with different heating systems (district heating or air-to-air heat pumps) and with or without electric vehicle (EV) charging. For these cases, detailed high-resolution time series for electricity consumption and PV generation are developed, based on measurement data, simulations, and weather data for a typical year. These are then used to create so-called “Frankenstein time series,” where four representative days are selected and combined to mimic a full year of operation. These are applied in dynamic laboratory testing, where real PV and battery systems from multiple manufacturers are tested under controlled yet realistic conditions. In parallel, a full-year simulation model is developed and calibrated against measurement data from the tests, and used to analyse technical and economic performance over longer periods. Systems from three suppliers (Ferroamp, Solis, and Huawei) are included in the study, with variations in battery capacity, PV capacity, and control strategies. The tested strategies include self-consumption optimization and peak power shaving. The systems are evaluated using several key performance indicators, such as system efficiency, self-consumption, self-sufficiency, energy flows to and from the grid, and battery efficiency. The results show that the dynamic testing method provides a realistic and relevant representation of system performance compared to full-year data. Battery storage generally increases both self-consumption and self-sufficiency, but the actual benefit is strongly influenced by system sizing and the chosen control strategy. From an economic perspective, the analysis shows that the PV system accounts for the largest share of savings when the battery is controlled to increase self-consumption or reduce peak demand. In many cases, the battery investment extends the payback period—often to more than 15 years without investment subsidies. Grid tariffs and electricity price variations play an important role in profitability, but to fully utilize the battery’s potential, combinations of control strategies should be applied. The report also analyses the systems’ ability to provide backup power (islanding operation). All studied systems can contribute to this to some extent, although additional equipment and/or installation measures are required. The results show that battery storage can increase household energy resilience, but the duration of supply during longer outages varies significantly between systems. Integration of the EV battery (vehicle-to-home, V2H) can significantly enhance this potential, but also introduces trade-offs in terms of reduced self-consumption and more complex system control. In conclusion, the study shows that dynamic and standardized testing is a relevant approach for fairly evaluating and comparing PV and battery systems. The actual value of the systems depends strongly on how they are sized and controlled based on household needs. The report highlights the importance of further development of testing methods, control strategies, and market models to better harness the potential of local energy systems in the energy transition.
Stockholm: RISE Research Institutes of Sweden AB , 2026. , p. 153