Fire tests on decks and bulkheads are normally performed according to IMCO's Resolution A 163. Tests on these elements can be performed at almost all official fire-technical laboratories. During recent years oil rigs and similar constructions have been built. In case of fire, constructions can be exposed to a more severe fire attack compared to the time-temperature curve in IMCO's Resolution A 163. At the division of fire technology at Statens Provningsanstalt an investigation has been made aiming at settling if fire tests according to the Mobil hydrocarbon time-temperature curve (HC-curve) can be performed. The project has been financed by Statens Provningsanstalt and Curt Kristiansson has been leader of the project.
SP-RAPP 1979:19