Determination of total silicon content in biomethane: Development of a validation approach for ISO 2613-1, as a practical application of the ISO guide under preparation: Biomethane – Performance evaluation for analytical systems
Institute of Metrology of Bosnia and Herzegovina, Sarajevo, Bosnia and Herzegovina.
Institute of Metrology of Bosnia and Herzegovina, Sarajevo, Bosnia and Herzegovina.
RISE Research Institutes of Sweden, Materials and Production, Applied Mechanics.ORCID iD: 0000-0002-4037-3106
RISE Research Institutes of Sweden, Materials and Production, Applied Mechanics.ORCID iD: 0000-0002-5289-4742
Show others and affiliations
2025 (English)In: Acta IMEKO, ISSN 0237-028X, Vol. 14, no 4.0Article in journal (Refereed) Published
Abstract [en]

This study presents a validation protocol for the atomic emission spectroscopy (AES) method for determining total silicon in biomethane, developed in alignment with ISO 2613-1:2023. The work serves as a practical demonstration, contributing to the forthcoming ISO validation guide for analytical methods assessing impurities in biomethane, prepared within ISO/TC 193 WG 25: Biomethane. The protocol describes the complete analytical process: absorption of volatile siloxane compounds in mineral acid, chemical derivatization into a suitable form for spectroscopy, and measurement of the resulting liquid sample using an optical plasma emission instrument. Method development included optimisation of sampling, derivatization, sample preparation, and quality control procedures. Validation was carried out through rigorous evaluation of linearity, stability, robustness, selectivity, sensitivity, precision, bias, and measurement uncertainty. Results confirmed the method’s reliability for detecting very low mass fractions of silicon (μg/kg range) originating from siloxane species, such as L2, L3, D4, and D5, in biomethane. By demonstrating both methodological robustness and practical applicability, this study provides a model example for ISO’s upcoming guidance on validation of analytical methods, supporting the harmonisation of impurity testing in renewable gases

Place, publisher, year, edition, pages
2025. Vol. 14, no 4.0
Keywords [en]
atomic emission spectroscopy, biomethane, measurement uncertainty, total silicon, validation
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:ri:diva-80062DOI: 10.21014/actaimeko.v14i4.2204Scopus ID: 2-s2.0-105024234704OAI: oai:DiVA.org:ri-80062DiVA, id: diva2:2024556
Available from: 2025-12-29 Created: 2025-12-29 Last updated: 2025-12-29Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Arrhenius, KarineHultmark, Sandra

Search in DiVA

By author/editor
Arrhenius, KarineHultmark, Sandra
By organisation
Applied Mechanics
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 36 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf