Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Impact of Water-Based Fire Suppression Systems on Combustion Products
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0001-9468-4586
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0002-8960-5799
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0001-9941-1675
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0009-0006-3249-9661
2025 (English)In: Fire technology, ISSN 0015-2684, E-ISSN 1572-8099, Vol. 61, no 4, p. 2441-Article in journal (Refereed) Published
Abstract [en]

This study aims to experimentally investigate the combustion products of fires suppressed/extinguished by two water-based fire suppression systems, namely, sprinklers and water mist systems. A total of thirteen experiments were conducted with various suppression system configurations, i.e., with a sprinkler, a low-pressure (LP) water mist, and a high-pressure (HP) water mist, at operating pressures ranging from 2 to 60 bar and water flow rate ranging from 10 to 206 L/min. Each experiment was conducted twice, except for the baseline experiment with no suppression. The fuel was a high-density polyethylene (HDPE) pallet placed on two wood pallets. During all the stages of fire development, suppression with water, and post-suppression, the combustion products were sampled through Fourier-Transform Infrared Spectroscopy (FTIR) using a gas analyzer capable of operating in high humidity. The main combustion products identified were CO2, CO, and H2O. In addition, NOx (nitrogen oxides), CxHy (light-weight hydrocarbons), and HCN were present in relatively high concentrations. All the tested fire suppression systems were effective in reducing the fire size and cooling down the gases. However, when the fire could not be immediately extinguished, the NOx, CxHy, and HCN concentrations were higher than those in the baseline experiment. Moreover, it is observed that the HP water mist system was more effective than the sprinkler and low-pressure water mist systems in reducing the amount of combustion gases during suppression, resulting in lower Fractional Effective Doses (FED). It was observed that the combustion products returned to ambient conditions after five minutes of deactivation. The results from this study provide much-needed validation data for the effectiveness of water-based suppression systems, not only in reducing the fire size but also in reducing the production of acute toxic gases, which is important for considerations regarding evacuation, firefighting, and post-extinguishment conditions. .

Place, publisher, year, edition, pages
Springer , 2025. Vol. 61, no 4, p. 2441-
Keywords [en]
Fire extinguishers; High pressure effects; Hose; Pallets; Sprinkler systems (irrigation); Wood products; Combustion products; Fire suppression; Fractional effective dose; Heat release; High-pressure water mists; Low pressures; Low-pressure water mist; Sprinkler; Water based; Water mist; Sprinkler systems (fire fighting)
National Category
Materials Engineering
Identifiers
URN: urn:nbn:se:ri:diva-78434DOI: 10.1007/s10694-024-01689-4Scopus ID: 2-s2.0-85217381146OAI: oai:DiVA.org:ri-78434DiVA, id: diva2:1998652
Note

This research is with the support from the Fire Research and Innovation Centre(FRIC) funded by the Research Council of Norway (No. 294649).

Available from: 2025-09-17 Created: 2025-09-17 Last updated: 2025-09-23Bibliographically approved

Open Access in DiVA

fulltext(2336 kB)147 downloads
File information
File name FULLTEXT01.pdfFile size 2336 kBChecksum SHA-512
df654bcfe747bc3232aa81754953f18a8be30f55421059424be5469f7fa0c984b182d293f3f1d00f5c93e7be27a30557e16e6163c68e433f49ccf657e43c3857
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Jiang, LeiZeinali, DavoodSarp Arsava, KemalSnersrud, Dag Olav

Search in DiVA

By author/editor
Jiang, LeiZeinali, DavoodSarp Arsava, KemalSnersrud, Dag Olav
By organisation
Fire and Safety
In the same journal
Fire technology
Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 147 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 7732 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf