Experience from field calibration of flow-meters with a mobile piston prover
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP - Statens Provningsanstalt.
1987 (English)Report (Refereed)
Abstract [en]

This technical report describes a new transportable measuring equipment developed at the National Measurement Laboratory for Volume Metrology, Borås, and intended to enable on-site calibration of large flow-meters. The availability of this equipment should mean shorter or no process stops because the meter on test does not have to be dismantled. It also leads to a better measurement and a more accurate calibration. With this equipment (Brooks compact prover) we can test meters with up to ten inch flange connections. We also have equipment for the accurate determination of volume in different types of tanks. Meters for a lot of different liquids have been tested, for example water, petrol, oil and liquified propane. The maximum flow rate is 26 000 l/min and maximum liquid temperature is +120 °C. All electrical measuring equipment can be used in hazardous areas (zone 1). Measurement occurs when an hydraulic valve closes thus forcing the flow to move a piston forward. On the piston are mounted detectors, with the help of which we can measure the time it takes for the piston to move through the cylinder. Knowing the cylinder volume (250 l) it is then possible to calculate the real flow rate. In series with the compact prover is a master meter. This is used for doublechecking or as a volume meter. The uncertainty in calibration measured in preliminary trials both in Borås and at Brooks (USA) is < 0,1 %.

Place, publisher, year, edition, pages
Borås: Statens Provningsanstalt (SP) , 1987. , p. 20
Series
SP Rapport, ISSN 0284-5172 ; 1987:24
Keywords [en]
flow-meter calibration, piston prover, in-line calibration
National Category
Other Engineering and Technologies
Identifiers
URN: urn:nbn:se:ri:diva-83035ISBN: 91-7848-066-3 (print)OAI: oai:DiVA.org:ri-83035DiVA, id: diva2:2113622
Note

SP-RAPP 1987:24

ISSN 0280 - 2503

Available from: 2026-10-28 Created: 2026-10-28 Last updated: 2026-10-28Bibliographically approved

Open Access in DiVA

Rapport(5753 kB)35 downloads
File information
File name FULLTEXT01.pdfFile size 5753 kBChecksum SHA-512
7726326cec886c6c4dec17553b3c4a1043546df3c572da0c8a6a6e2f6b388d19885e3b5b128704999d688c0944411a3e906fd4e07adc9d9dd88d80d227c97167
Type fulltextMimetype application/pdf

By organisation
SP - Statens Provningsanstalt
Other Engineering and Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 35 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 8178 hits
2122232425262724 of 64
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf