CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
KORROSIONSINHIBITORER FÖR ALUMINIUM I VÄTSKEBERÖRDA SYSTEM: En litteraturundersökning
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP – Sveriges Provnings- och Forskningsinstitut.
1989 (Swedish)Report (Refereed)
Abstract [en]

The main objective of this literature survey was to search for stable inhibitors that effectively prevent corrosion on aluminium in contact with heat transfer fluids at temperatures above 100 °C, preferably above 130 °C. The corrosion behaviour of aluminium is mostly dependent of the surface film of aluminium oxide, for it is the properties of this film that provide aluminium with its resistance to corrosion. When a fresh aluminium surface is created and exposed to air, it oxidizes rapidly, and acquires a compact, adherent, protective film of aluminium oxide which tends to resist further oxidation. On a freshly rolled aluminium sheet the film is extremely thin about 0.01 um. When aluminium is immersed in water, the oxide film thickens rapidly, at a rate that increases with temperature. It is commonly stated that the oxide film is stable over a pH range of about 4.5 to 8.5. But there are exceptions. Light gauge aluminium solar heat collector panels operating on aqueous glycol heat transfer fluids appear to be attractive except for the critical problem of aluminium corrosion. The corrosion resistance of aluminium is marginal even in pure uninhibited ethylene glycol solutions up to 100 °C. However, this marginal corrosion resistance is enormously reduced in the presence of chloride or heavy metal ions (e.g. Cu2+ and Fe3+). A similar conclusion was reached for aluminium/propylene glycol combinations. It was found that inhibitors used in commercial automotive coolants are effective only at temperatures below 100 °C, and that pitting corrosion induced by chloride and heavy metal ions reappears at higher temperatures. But the combined use of zinc powder and conventional corrosion inhibitors compatible with aqueous glycol solutions is 100 % effective in stopping all aluminium corrosion problems at temperatures up to 130 °C, even in solutions initially containing chloride and heavy metal ions.

Place, publisher, year, edition, pages
Borås: Statens Provningsanstalt (SP) , 1989. , p. 31
Series
SP Rapport, ISSN 0284-5172 ; 1989:18
National Category
Surface- and Corrosion Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82969ISBN: 91-7848-168-6 (print)OAI: oai:DiVA.org:ri-82969DiVA, id: diva2:2110266
Note

SP Rapport 1989:18

Available from: 2026-10-14 Created: 2026-10-14 Last updated: 2026-10-14Bibliographically approved

Open Access in DiVA

Rapport(11106 kB)56 downloads
File information
File name FULLTEXT01.pdfFile size 11106 kBChecksum SHA-512
661d1f962d52f28e357b9ac73ed81e90c5b5d291124fafe79afe136ffe1a4b86bf5757097a9b9d7f2dc7a2220aaad835946cd1674002a290c5ec2fa95bb79b93
Type fulltextMimetype application/pdf

By organisation
SP – Sveriges Provnings- och Forskningsinstitut
Surface- and Corrosion Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 56 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 23155 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf