4647484950515249 of 139
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Brandsektionering genom vattenbegjutning
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP - Statens Provningsanstalt.
1986 (Swedish)Report (Refereed)
Abstract [en]

The aim of the study was to investigate the possibility of using water cooled thin wall structures in fire compartmentation of industrial buildings. How to prevent fire spread through doors, windows or other openings in the fire walls has also been included in this study. A litterature investigation about water cooling of fire exposed structures has been made. This shows that in offshore and oil terminals water sprays have been applied in cooling fire exposed structures. As fire compartmentation water, according to the litterature investigation, is not used in Sweden. Other countries have not reported to have such a kind of compartmentation method, either. Results from oil storage tank tests show that a water flow density of 10 l/min/m² is essential to completely wet the surface of the tank. If the same flow density was applied to large industrial walls of thin plate, the water demand and hence the costs of walls with pumps and pipings would be compareable to conventional walls of concrete. If economical winnings with this compartmentation method would be made, the water demand should be reduced. The water demand could be essentially reduced by covering the wall by a rough layer of some fire proof material. Hence, the water drainage could be smaller and water would have more time on the wall surface to vaporize. Thus the heat of vapourization could cool the wall more effectively. According to theory it is essential not to allow the metal surface to get hotter than about 300 °C. Above this temperature the water drops do not get stuck on the metal surface resulting a drastic increase of water demand.

Place, publisher, year, edition, pages
Borås: Statens Provningsanstalt (SP) , 1986. , p. 42
Series
SP Rapport, ISSN 0284-5172 ; 1987:30
Keywords [en]
Spray cooling, fire compartmentation, fire wall, thin plate wall, water, fire spread, doors, ports
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82845ISBN: 91-7848-071-X (print)OAI: oai:DiVA.org:ri-82845DiVA, id: diva2:2106489
Note

SP-RAPP 1987:30

ISSN 0280 - 2503

Available from: 2026-09-30 Created: 2026-09-30 Last updated: 2026-09-30Bibliographically approved

Open Access in DiVA

Rapport(10570 kB)19 downloads
File information
File name FULLTEXT01.pdfFile size 10570 kBChecksum SHA-512
1a2042f505fac8360c408b5b40294043d2ab1c37ebf9fcadcf33a7f6e73c48d3009445fc6c94e7e05c2e3afb99c11c581829f9eabcf525c5b50d8a8605767d4f
Type fulltextMimetype application/pdf

By organisation
SP - Statens Provningsanstalt
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 530 hits
4647484950515249 of 139
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf