System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ventilationsteknisk undersökning av storkökskåpor
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP – Sveriges Provnings- och Forskningsinstitut.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP – Sveriges Provnings- och Forskningsinstitut.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP – Sveriges Provnings- och Forskningsinstitut.
1989 (Swedish)Report (Refereed)
Abstract [en]

Study of Large Scale Kitchen Range Hoods. A field study of six different large scale kitchen range hoods has been carried out. The aim has been to measure both how well a contamination produced under the hood is taken care of (hood efficiency) and the thermal comfort. The results have been compared with recommendations according to AFS (the National Board of Occupational Safety and Health) 1980:20. To get the influence of variation in energy input to heatsource and changes in exhaust airflow rate under control, a laboratory kitchen has been built up. The measured hood efficiency varies between 83 % and 95 %, with most of the kitchens in the range of 90-95 %. The equivalent temperature measured 0.5 m from a heat source, was in most cases about 28 °C with a maximum of 32 °C. One of the hoods was equipped with an internal injection of supply air. In this case we measured both a very high hood efficiency and a very good thermal comfort. Measurement in the laboratory kitchen showed that the hood efficiency depended very much on the exhaust airflow rate. Changes in the input energy to the heatsources gave only a minor dependence. To reach a hood efficiency of about 95 %, it seems necessary to maintain a mean velocity of at least 0.1 m/s into the hood cross-section. The thermal comfort is strongly depending on the input energy to the heatsources, and less on the airflow rate. With a conventional volume hood as a reference, it should be possible to compare different types of hoods in a laboratory.

Place, publisher, year, edition, pages
Borås: Swedish National Testing and Research Institute (SP) , 1989. , p. 35
Series
SP Rapport, ISSN 0284-5172 ; 1989:40
Keywords [en]
Hood efficiency, tracer gas, large scale kitchen range hoods
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:ri:diva-82836ISBN: 91-7848-190-2 (print)OAI: oai:DiVA.org:ri-82836DiVA, id: diva2:2105259
Note

SP RAPPORT 1989:40

Available from: 2026-09-25 Created: 2026-09-25 Last updated: 2026-09-25Bibliographically approved

Open Access in DiVA

Rapport(8048 kB)16 downloads
File information
File name FULLTEXT01.pdfFile size 8048 kBChecksum SHA-512
0fbdeab2fe847124bb6903117f773cdb6e17ed83be28638ab832938355c8272dcda9ca7e5eb0f98c73abf19d2713885d3d8da5d1a5eea698459909967f2d298b
Type fulltextMimetype application/pdf

By organisation
SP – Sveriges Provnings- och Forskningsinstitut
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 563 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf