CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Nionde komparationen mellan riksnormalen för kilogrammet och Statens Provningsanstalts huvudnormaler
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP - Statens Provningsanstalt.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP - Statens Provningsanstalt.
1981 (Swedish)Report (Refereed)
Abstract [en]

Measurements of mass in Sweden are based on the mass of the Swedish platinum-iridium prototype no 40. The prototype is traceable to the mass of the international prototype and is certified by BIPM in 1889 and 1948. In order to control the traceability of the prototype in accordance to the metre convention it has been decided to subject the prototype to a comparison at BIPM involving a cleaning procedure and a subsequent calibration against the international prototype. The transport of the damageable prototype is always adventurous irrespective of how high the safety precautions are. Therefore a comparison between two of the mass standards of the Statens provningsanstalt (H and MJV1) and the prototype P have been carried out in order to ensure a good secondary standard during the absence of the prototype. The balance which was used at the comparison was a newly acquired mass comparator of two knives type, manufactured by Voland Co. As the aim of the comparison was, if possible, to determine 1 kg with an inaccuracy up to a few ug, such a weighing requires the temperature of the air, the weights and the whole balance to be kept within some hundredths of a degree C. Other error sources which were kept under strict control were air pressure, air humidity and CO2 concentration. The quantitative evaluation of the air density in the laboratory was done by a computer, based on a new formula recommended by BIPM. Because of the high accuracy, which is obtained by doing the comparison in "triangle", the weights H (brass) and MJV1 (stainless steel) were examined by a complete comparison with the prototype P (1 kg - 0.039 mg) in three combinations according to the following scheme: H - P, MJV1 - P, MJV1 - H. To get a sufficient statistical data each "triangle" was repeated 9 times. Accordingly inalles 27 measurements were done. The following mean values and inaccuracies were found for H and MJV1: H = 1 kg + 6.80 mg ± 0.02 mg MJV1 = 1 kg + 0.15 mg ± 0.02 mg

Place, publisher, year, edition, pages
Borås, 1981. , p. 36
Series
SP Rapport, ISSN 0284-5172 ; 1981:18
National Category
Other Engineering and Technologies
Identifiers
URN: urn:nbn:se:ri:diva-82623OAI: oai:DiVA.org:ri-82623DiVA, id: diva2:2097632
Note

SP-RAPP 1981:18

Available from: 2026-09-02 Created: 2026-09-02 Last updated: 2026-09-02Bibliographically approved

Open Access in DiVA

Rapport(10435 kB)9 downloads
File information
File name FULLTEXT01.pdfFile size 10435 kBChecksum SHA-512
3464933d17d86d5bd0683f2ed5b91b20fd55ebcd6c07b4a21b5813327fbce37bc603ed96c0e61b64a985fd84c281dd3bd12908bbe7819c5ea733cec7dae5daa2
Type fulltextMimetype application/pdf

By organisation
SP - Statens Provningsanstalt
Other Engineering and Technologies

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 76 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf