Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Composition of foods including added water using microwave dielectric spectra
2001 (Engelska)Ingår i: Food Control, ISSN 0956-7135, E-ISSN 1873-7129, Vol. 12, nr 7, s. 467-482Artikel i tidskrift (Refereegranskat)
Abstract [en]

The added water content of fresh and untreated pork, poultry, fish and prawns was adjusted either by dipping in polyphosphate and salt solutions of known concentrations for controlled periods, or by injection (pork) with polyphosphate and salt solutions. Mixtures were prepared from treated and untreated fish and other foods (milk and flour). Liquid uptake was determined by the weight gain of samples. The proximate composition of the samples was determined: water, fat, protein, NaCl and phosphorus (for polyphosphate content). Complex dielectric spectra of each product were measured at known temperatures and at 31 frequencies in the range 0.2-12 GHz using an automatic network analyser (ANA) and a 3.0 mm open-ended coaxial sensor. The spectra were subjected to various procedures. Principal component analysis (PCA) using the individual complex components. Regression of the composition data against the principal components to obtain prediction formulae for composition including liquid uptake (internal cross-validation). Regression of the composition data against raw spectral data and against other composition variables to obtain similar formulae. In order to design a simpler instrument, the effect on accuracy was studied of reducing the number of frequencies in the spectrum and its range. The slight loss of accuracy engendered by using only five or six frequencies was acceptable. The accuracy of the method in predicting liquid uptake and composition was good. Using one of the compositional variables in the calibration made it equivalent to accuracy obtained by proximate analysis, which was the limiting factor. Measurements on solutions of glycerol, NaCl and water with precisely known composition demonstrated that the intrinsic accuracy of the instrument was far better. A prototype instrument was built and validated using samples of prawns and herring. © 2001 Elsevier Science Ltd.

Ort, förlag, år, upplaga, sidor
2001. Vol. 12, nr 7, s. 467-482
Nyckelord [en]
Food Engineering
Nyckelord [sv]
Livsmedelsteknik
Nationell ämneskategori
Livsmedelsvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-8581DOI: 10.1016/S0956-7135(01)00021-4OAI: oai:DiVA.org:ri-8581DiVA, id: diva2:966453
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltexthttp://www.scopus.com/inward/record.url?eid=2-s2.0-18044403438&partnerID=40&md5=4a99e83bda4b0bc51471495772755406
I samma tidskrift
Food Control
Livsmedelsvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 81 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf