Large scale test on a steel column exposed to localized fire
Luleå University of Technology, Sweden.
RISE., SP – Sveriges Tekniska Forskningsinstitut. Luleå University of Technology, Sweden.ORCID-id: 0000-0001-8670-062x
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research. Luleå University of Technology, Sweden.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research.ORCID-id: 0000-0002-4551-1045
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Journal of Structural Fire Engineering, ISSN 2040-2317, E-ISSN 2040-2325, Vol. 5, nr 2, s. 147-160Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A localized fire is a fire which in a compartment is unlikely to reach flash-over and uniform temperature distribution. Designing for localized fires is generally more difficult than for flash-over compartment fires because of the complexity of the problem. There is also a lack of experimental data. We report here on a full scale test series on a steel column exposed to localizedfires. The setup is a 6 meters tall hollow circular column, I= 200 mm with a steel thickness of 10 mm. The unloaded column was hanging centrally above different pool fires. Temperatures of gas and steel were measured by thermocouples, and adiabatic surface temperatures at the steel surface were measured by plate thermometers of various designs. The results are compared with estimates based on Eurocode 1991-1-2 which in all cases studied overestimate the thermal impact for this setup. The input from plate thermometers was used to compute the steel temperatures using finite element methods. Excellent agreement was found if the radiation exchange within the column due to asymmetry of the exposure was taken into account.

Ort, förlag, år, upplaga, sidor
2014. Vol. 5, nr 2, s. 147-160
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-6746DOI: 10.1260/2040-2317.5.2.147Scopus ID: 2-s2.0-84901978770Lokalt ID: 23770OAI: oai:DiVA.org:ri-6746DiVA, id: diva2:964586
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Sjöström, JohanLange, David

Sök vidare i DiVA

Av författaren/redaktören
Sjöström, JohanLange, David
Av organisationen
SP – Sveriges Tekniska ForskningsinstitutSP Fire Research
I samma tidskrift
Journal of Structural Fire Engineering
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 112 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf