Analysis of toxic effluents released from PVC carpet under different fire conditions
University of Central Lancashire, United Kingdom.
University of Central Lancashire, United Kingdom.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP Sveriges tekniska forskningsinstitut / Brandteknik, forskning (BRf ).ORCID-id: 0000-0002-6430-6602
Stockholm University, Sweden.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Chemosphere, ISSN 0045-6535, E-ISSN 1879-1298, Vol. 90, nr 1, s. 65-71Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A large number of investigations have been reported on minimising the PAH and PCDD/F yields during controlled combustion, such as incineration. This study is an attempt to quantify acute and chronic toxicants including PAH and PCDD/F in conditions relating to unwanted fires.This paper investigates distribution patterns of fire effluents between gas and aerosol phase, and the different particle size-ranges produced under different fire conditions. PVC carpet was selected as the fuel as a precursor for both PAH and PCDD/F. In order to generate fire effluents under controlled fire conditions, the steady-state tube furnace, was chosen as the physical fire model. Fire scenarios included oxidative pyrolysis, well-ventilated and under-ventilated fires. Fire effluent measurements included: carbon monoxide, carbon dioxide, hydrogen chloride, polycyclic aromatic hydrocarbons, chlorinated dibenzo-dioxins and furans and soot. The distribution patterns between gas and particle phase, and the size-ranges of the particles produced in these fires together with their chemical composition is also reported.Significant quantities of respirable submicron particles were detected, together with a range of PAHs. Lower levels of halogenated dioxins were detected in the fire residue compared with those found in other studies. Nevertheless, the findings do have implications for the health and safety of fire and rescue personnel, fire investigators, and other individuals exposed to the residue from unwanted fires.

Ort, förlag, år, upplaga, sidor
2013. Vol. 90, nr 1, s. 65-71
Nyckelord [en]
Dioxins, Furans, Hydrogen chloride, Particles, Polycyclic aromatic hydrocarbons, Steady state tube furnace
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-6446DOI: 10.1016/j.chemosphere.2012.07.037Scopus ID: 2-s2.0-84868469268Lokalt ID: 14658OAI: oai:DiVA.org:ri-6446DiVA, id: diva2:964284
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Blomqvist, Per

Sök vidare i DiVA

Av författaren/redaktören
Blomqvist, Per
Av organisationen
SP Sveriges tekniska forskningsinstitut / Brandteknik, forskning (BRf )
I samma tidskrift
Chemosphere
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 49 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf