Strength properties of wood adhesives after exposure to fire. Nordtest project 1482-00
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Bygg och Mekanik.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Bygg och Mekanik.
2001 (Engelska)Rapport (Refereegranskat)
Abstract [en]

Nordtest and SP Swedish National Testing and Research Institute (SP) have financed a study to draft a common Nordic test method to classify wood adhesives for structural purposes according to strength properties after fire exposure. The study has been planned and carried out in cooperation between SP and Norwegian Institute of Wood Technology (NTI) with participation of Otto Graf Institute in Germany (FMPA). Glulam beams produced with six different adhesives have been exposed to fire. Temperature distribution during the fire exposure test, weight loss and charring rate have been determined. Shear strength of glulines and wood have been determined and delamination tests have been carried out on samples exposed to fire and samples not exposed to fire. Short term shear strength and creep rupture tests at elevated temperature have been carried out on samples with wood adhesives used in the test. Preliminary calculations of temperature distributions during fire in wooden members protected against direct fire exposure by gypsum board have been made. The results of the study on beams not protected by gypsum indicate that a wood adhesive that has shown favourable results in a creep rupture test at elevated temperature (80 °C) also will perform well during and after direct fire exposure. A static load test at elevated temperature can be used as an efficient and cheap method as an alternative to fire exposure tests of glued products for structural use. The results of the preliminary calculations on temperature distributions during fire exposure of gypsum protected smaller wood members indicate that under certain circumstances, the temperature can reach and stay at temperatures above 120 °C for a longer period of time. An additional test at higher temperature could be needed for adhesives intended for such structures.

Ort, förlag, år, upplaga, sidor
2001. , s. 30
Serie
SP Rapport, ISSN 0284-5172 ; 2001:35
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-4553Lokalt ID: 621ISBN: 91-7848-883-4 (tryckt)OAI: oai:DiVA.org:ri-4553DiVA, id: diva2:962191
Tillgänglig från: 2016-09-07 Skapad: 2016-09-07 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

fulltext(707 kB)257 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 707 kBChecksumma SHA-512
82085aab4b09cebf7529b6afecc47ec5ea3f7fb888f5500abf7aa4e6f24cfb41d330ff4c914fbfaf722d33a146b60053444b9ebf0916190fb17f3be9b871b898
Typ fulltextMimetyp application/pdf

Av organisationen
SP Bygg och Mekanik
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 258 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 212 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf