Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Performance of various water-based fire suppression systems in tunnels with longitudinal ventilation
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0001-7744-2390
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0002-9340-6768
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0002-6264-7307
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet. Luleå University of Technology, Sweden.ORCID-id: 0000-0002-7140-4737
2024 (Engelska)Ingår i: Fire safety journal, ISSN 0379-7112, E-ISSN 1873-7226, Vol. 146, artikel-id 104141Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Low pressure, medium pressure and high pressure water-based fire suppression systems were tested in a medium scale tunnel (scale 1:3). The primary objective was to investigate which of these systems are most effective in the suppression or control of different types of tunnel fires. The default low, medium and high pressure systems refer to full scale water flow rates of 10 mm/min, 6.8 mm/min and 3.7 mm/min, respectively. Some other water densities were also tested to investigate the effects, as well as different ventilation velocities and activation criteria. Several series of fire tests were conducted for different fire scenarios. The fire scenarios considered included idle wood pallet fires, loosely packed wood crib fires, loosely packed wood and plastic crib fires, and pool fires, with or without a top cover on the fuel load. Comparisons of the three default systems based on the three parameters: heat release rate, energy released and possibility of fire spread, show that the performance of the default low pressure system is usually the most effective based on the parameters studied. The default high pressure system usually yields results less effective in comparison to the default low pressure system. The performance of the default medium pressure system usually lies in between them. The high pressure system behaves very differently in comparison to the others, in terms of tunnel ventilation velocity, water density, operating pressure, and the presence of the top cover. © 2024 The Authors

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2024. Vol. 146, artikel-id 104141
Nyckelord [en]
Fire protection; Flammability testing; Flow of water; Ventilation; Fire suppression; Heat release; Heat release rate; Low pressure systems; Medium pressure; Operating pressure; Performance; Release rate; Tunnel fires; Water density; Fires
Nationell ämneskategori
Samhällsbyggnadsteknik
Identifikatorer
URN: urn:nbn:se:ri:diva-72758DOI: 10.1016/j.firesaf.2024.104141Scopus ID: 2-s2.0-85189859035OAI: oai:DiVA.org:ri-72758DiVA, id: diva2:1858312
Anmärkning

The work was financially supported by the Swedish Research Council Formas (2019-00521), which is gratefully acknowledged. The authors would also like to express their gratitude to Prof. Patrick van Hees at Lund University for his valuable input in the test planning process. Thanks also to our colleague Joel Blom, and other technicians at RISE for the great assistance in conducting the tests, and the Södra Älvsborg's Rescue Service for the support on site.

Tillgänglig från: 2024-05-16 Skapad: 2024-05-16 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

fulltext(3329 kB)335 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3329 kBChecksumma SHA-512
377f0ab4aae1b7511ff4a04001ba82bcb0c98e03f1c03b094f7b77b218cbd8330745b3aa2f1185435f82dba83fba8f1da9ff9f23cb0a6559cb68737e4fdc60d0
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Li, Ying ZhenIngason, HaukurArvidson, MagnusFörsth, Michael

Sök vidare i DiVA

Av författaren/redaktören
Li, Ying ZhenIngason, HaukurArvidson, MagnusFörsth, Michael
Av organisationen
Brand och Säkerhet
I samma tidskrift
Fire safety journal
Samhällsbyggnadsteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 338 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 265 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf