Exposure from mass timber compartment fires to facades
RISE Research Institutes of Sweden, Säkerhet och transport, Brandteknik. (Brandforskning)ORCID-id: 0000-0001-8670-062x
RISE Research Institutes of Sweden, Säkerhet och transport, Brandteknik.ORCID-id: 0000-0002-4675-4778
RISE Research Institutes of Sweden.
Visa övriga samt affilieringar
2021 (Engelska)Rapport (Övrigt vetenskapligt)
Abstract [en]

Different countries world-wide have different legislation concerning the performance of facades exposed to fire and often significantly different ways to assess this performance. Although it is recognized that standard façade fire testing aims to distinguish façade systems that limit fire spread to an acceptable level from systems that do not, it has historically been considered important that the fire exposure of such tests is representative for real fires.

In this study five real scale compartment fire tests, constructed of Cross Laminated Timber and Glued laminated timber were performed with instrumentation on a façade extension above the ventilation openings, providing a means to compare façade performance tests against the exposure generated by realistic compartment fires. The fuel load and openings of four of these tests were determined from a statistical analysis to represent severe fire exposure within a realistic range. Of these tests the surface areas of exposed Cross Laminated Timber and Glued Laminated Timber were varied, allowing an assessment of the influence having internal areas of exposed timber surfaces on the façade fire exposure.

For these tests, an increase of roughly 40 m2 exposed surface area (from ~54 to ~94 m2 or from 113 % to 196 % of the floor area) resulted in a temperature increase of roughly 100 to 130 °C at the façade at all heights up to 3.5 m above the opening. Additionally, an increased fire plume height of 0 to 1 m was observed. The most significant effect of increased exposed areas was a prolonged duration of the flashover phase.

The British BS 8414 standard façade fire tests and the recently proposed European façade fire test have been identified to be the most representative for the tested residential fire scenarios in terms of façade fire exposure. Temperature measurements of the North American methods (NFPA 285 and CAN/ULC-S134) are towards the end of the tests also close to the those of the compartment tests. The Swedish SP Fire 105 test imposes the lowest exposure for a relatively short duration to the façade. It should, however, be noted that a lower exposure in the standard test method does not with necessity mean lower threshold for regulatory compliance as the test criteria also differ between different countries.

One of the tests were characteristic of open plan office buildings and it was shown that the fire exposure is both shorter and lower compared to typical residential compartment tests. All standard tests that were used for comparison here exhibited both longer and higher exposure than the office building compartment test.

Ort, förlag, år, upplaga, sidor
Borås, 2021. , s. 102
Serie
RISE Rapport ; 2021:39
Nyckelord [en]
Mass Timber, CLT, Fire, Compartment fire, Glued laminated timber, façade, test
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:ri:diva-56582ISBN: 978-91-89385-24-5 (digital)OAI: oai:DiVA.org:ri-56582DiVA, id: diva2:1594601
Forskningsfinansiär
BrandforskTillgänglig från: 2021-09-15 Skapad: 2021-09-15 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Report Exposure to facades(14197 kB)695 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 14197 kBChecksumma SHA-512
38f7135b895d4703c1932a9283bda8c8d52a043b4849849c1d2ee6314e6cb4114b7fd826c960c1fbed3706ba9ffecfe1fc2fa842ccfbeb696ccce4aa36baa86f
Typ fulltextMimetyp application/pdf

Person

Sjöström, JohanBrandon, DanielTemple, Alastair

Sök vidare i DiVA

Av författaren/redaktören
Sjöström, JohanBrandon, DanielTemple, Alastair
Av organisationen
BrandteknikRISE Research Institutes of Sweden
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 704 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1397 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf