High-Frequency Current Transformer Design and Implementation Considerations for Wideband Partial Discharge Applications
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0002-8581-012x
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-5044-8266
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0002-1164-8254
2021 (Engelska)Ingår i: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 70, artikel-id 6003809Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

High-frequency current transformers are popular noninvasive inductive wideband sensors. Despite simplicity in design and operational principle, implementation of such sensors for partial discharge applications requires careful consideration, particularly in the higher frequency range where traveling wave attenuation and distortion is relevant. First, the role of design variables, including core materials, winding design, and shielding practices on sensor sensitivity and frequency characteristics (transfer impedance) are presented. Next, the suitability of the constructed sensors for partial discharge applications is assessed. The designed wideband sensors are suitable for laboratory applications with standard measurement circuits and controlled conditions. The low-level magnitude and frequency spectrum of the discharge pulses hinders signal integrity in relation to the placement of the sensors within the measurement circuit, signal amplification, and pulse repetition rate (pulse resolution). To enable most stringent detection levels under 1 pC, efforts are needed in distortionless amplifier design and interference mitigation. 

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers Inc. , 2021. Vol. 70, artikel-id 6003809
Nyckelord [en]
Apertures, Current measurement, current transformers, frequency-domain analysis, high-voltage techniques, partial discharge measurement, Partial discharges, Sensitivity, time-domain analysis, Voltage measurement, Wideband
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-52227DOI: 10.1109/TIM.2021.3052002Scopus ID: 2-s2.0-85099723741OAI: oai:DiVA.org:ri-52227DiVA, id: diva2:1526047
Tillgänglig från: 2021-02-05 Skapad: 2021-02-05 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Kluss, JoniElg, Alf PeterWingqvist, Claes

Sök vidare i DiVA

Av författaren/redaktören
Kluss, JoniElg, Alf PeterWingqvist, Claes
Av organisationen
Mätteknik
I samma tidskrift
IEEE Transactions on Instrumentation and Measurement
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 205 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf