Driftmeddelande
För närvarande är det driftstörningar. Felsökning pågår.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Preparation and characterisation of a sensing system for wireless pH measurements in vivo, in a rumen of a cow
RISE - Research Institutes of Sweden (2017-2019), ICT, Acreo.
RISE - Research Institutes of Sweden (2017-2019), ICT, Acreo.ORCID-id: 0000-0002-3618-9496
RISE - Research Institutes of Sweden (2017-2019), ICT, Acreo.
RISE - Research Institutes of Sweden (2017-2019), ICT, Acreo.ORCID-id: 0000-0003-0792-7039
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 242, s. 637-644Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We describe a sensing system that is able to measure pH in-vivo, in the rumen of a cow, in real time. The sensing principle is based on gravimetric transduction using a magnetoelastic ribbon functionalized by pH-sensitive nanobeads that is placed in the rumen where it is actuated and read-out wirelessly. We describe a generic procedure that enables one to deposit monolayers or multilayers of nano- and micro beads onto virtually any substrate. The topography of the resulting layers as well as interlayer coverages were characterised using optical microscopy and scanning profilometry. First we determined performance of the system in-vitro, in phosphate-buffered saline, in McDougall's buffer and in a rumen fluid. Thereafter we also performed in-vivo measurements. Using buffers we determined pH response in the liquids both at the fundamental frequency of the functionalised foils, and at the 1st overtone. We argue that observed frequency changes vs pH are mainly due to changes of trapped liquid when the bead layers shrink or expand as a response to changed pH. The data obtained from the pH response of magnetoelastic foils at different bead coverages was modelled by a simple two-parameter model that corroborates this assumption.

Ort, förlag, år, upplaga, sidor
2017. Vol. 242, s. 637-644
Nyckelord [en]
Layer-by-layer deposition, Magnetoelastic resonance, Mussel adhesive protein, Nanoparticle multilayers, pH sensitive polymer, Rumen pH, Deposition, Multilayers, Potentiometric sensors, Layer by layer deposition, Magneto-elastic, Mussel adhesive proteins, Ph sensitive polymers, pH sensors
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-29324DOI: 10.1016/j.snb.2016.11.089Scopus ID: 2-s2.0-84998829105OAI: oai:DiVA.org:ri-29324DiVA, id: diva2:1095106
Tillgänglig från: 2017-05-12 Skapad: 2017-05-12 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Ilver, DagJonasson, ChristianJohansson, ChristerKrozer, Anatol

Sök vidare i DiVA

Av författaren/redaktören
Ilver, DagJonasson, ChristianJohansson, ChristerKrozer, Anatol
Av organisationen
Acreo
I samma tidskrift
Sensors and actuators. B, Chemical
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 118 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf