RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Belysning som stöd vid räddningsinsats i rökfylld tunnel
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0002-9598-0958
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0001-7145-0461
2020 (Svenska)Rapport (Övrigt vetenskapligt)
Abstract [en]

Lighting as support for fire and rescue operations in a smoke-filled tunnel This report presents a series of full-scale movement experiments conducted in the Masthamn tunnel in Stockholm to investigate how different lighting fixtures affect the BA-firefighters’ moving speed in smoke-filled tunnel environment. Four professional firefighters performed 14 tests under different lighting conditions: no lighting (reference tests), point source lighting at 24 m distance, point source lighting at 8 m distance, and continuous LED lighting. The tests were conducted in artificial smoke with visibility below 3 m and without the use of flashlights or thermal imaging cameras. Movement was documented using thermal imaging, while breathing air consumption was measured using telemetry and manual air pressure readings. The results show that lighting configuration had a clear influence on moving speed. Continuous LED lighting and 8 m point source lighting enabled substantially higher movement speeds than the 24 m point source lighting or the reference tests with no lighting. The presence of a handrail also improved orientation and moving speed, even in the absence of active lighting. Air consumption varied more between individual firefighters than between the different tests, although stretcher transport resulted as expected in generally higher air consumption. The findings indicate that continuous evacuation lighting can improve not only evacuation conditions but also the operational capability of BA-firefighting in smoke-filled tunnel environments.

Ort, förlag, år, upplaga, sidor
RISE Research Institutes of Sweden , 2020. , s. 17
Serie
RISE Rapport ; 2020:97
Nyckelord [en]
Fire and rescue operations, lighting conditions, tunnels, moving speed
Nationell ämneskategori
Infrastrukturteknik
Identifikatorer
URN: urn:nbn:se:ri:diva-81717ISBN: 978-91-90109-93-9 (tryckt)OAI: oai:DiVA.org:ri-81717DiVA, id: diva2:2064531
Anmärkning

QC 20260602

Tillgänglig från: 2026-06-02 Skapad: 2026-06-02 Senast uppdaterad: 2026-06-02Bibliografiskt granskad

Open Access i DiVA

fulltext(1202 kB)22 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1202 kBChecksumma SHA-512
9c1224845c17335fa72d312db68e9b02c22fc5fb7cc0d301a358465afe30544094dd7a7bbbd699629e5f2c26865b238508c21d6f9b702d86ce56cd076896a7f8
Typ fulltextMimetyp application/pdf

Person

Kumm, MiaStorm, Artur

Sök vidare i DiVA

Av författaren/redaktören
Kumm, MiaStorm, Artur
Av organisationen
Brand och Säkerhet
Infrastrukturteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 256 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf