Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Composition of foods including added water using microwave dielectric spectra
2001 (engelsk)Inngår i: Food Control, ISSN 0956-7135, E-ISSN 1873-7129, Vol. 12, nr 7, s. 467-482Artikkel i tidsskrift (Fagfellevurdert)
Abstract [en]

The added water content of fresh and untreated pork, poultry, fish and prawns was adjusted either by dipping in polyphosphate and salt solutions of known concentrations for controlled periods, or by injection (pork) with polyphosphate and salt solutions. Mixtures were prepared from treated and untreated fish and other foods (milk and flour). Liquid uptake was determined by the weight gain of samples. The proximate composition of the samples was determined: water, fat, protein, NaCl and phosphorus (for polyphosphate content). Complex dielectric spectra of each product were measured at known temperatures and at 31 frequencies in the range 0.2-12 GHz using an automatic network analyser (ANA) and a 3.0 mm open-ended coaxial sensor. The spectra were subjected to various procedures. Principal component analysis (PCA) using the individual complex components. Regression of the composition data against the principal components to obtain prediction formulae for composition including liquid uptake (internal cross-validation). Regression of the composition data against raw spectral data and against other composition variables to obtain similar formulae. In order to design a simpler instrument, the effect on accuracy was studied of reducing the number of frequencies in the spectrum and its range. The slight loss of accuracy engendered by using only five or six frequencies was acceptable. The accuracy of the method in predicting liquid uptake and composition was good. Using one of the compositional variables in the calibration made it equivalent to accuracy obtained by proximate analysis, which was the limiting factor. Measurements on solutions of glycerol, NaCl and water with precisely known composition demonstrated that the intrinsic accuracy of the instrument was far better. A prototype instrument was built and validated using samples of prawns and herring. © 2001 Elsevier Science Ltd.

sted, utgiver, år, opplag, sider
2001. Vol. 12, nr 7, s. 467-482
Emneord [en]
Food Engineering
Emneord [sv]
Livsmedelsteknik
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-8581DOI: 10.1016/S0956-7135(01)00021-4OAI: oai:DiVA.org:ri-8581DiVA, id: diva2:966453
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fullteksthttp://www.scopus.com/inward/record.url?eid=2-s2.0-18044403438&partnerID=40&md5=4a99e83bda4b0bc51471495772755406
I samme tidsskrift
Food Control

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 81 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0