Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Durability of concrete caissons made in floating docks
ACCIONA, Spain.
ACCIONA, Spain.
ACCIONA, Spain.
ACCIONA, Spain.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Concrete 2015: Proceedings of the 27th Biennial National Conference of the Concrete Institute of Australia in conjunction with the 69th RILEM Week "Construction Innovations, Research into Practice", Institute of Australia , 2015, s. 894-903Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

ACCIONA Infrastructure, a Spanish contractor, uses the caisson method for the construction ofbreakwater structures. One of its floating docks, Kugira, is one of the largest of its kind in the world and itcan produce concrete caissons measuring 70 m long by 36 m wide and 35 m high. Concrete caissonsmade in floating docks are gradually immersed in sea water as they are built; thus, the set concrete isexposed to sea water at a very early stage, within 18 to 48 hours after casting in sliding formwork. In orderto study the durability of slag concrete using this construction method, the properties of concrete exposedto sea water at a very young age have been tested. Specimens were exposed to artificial sea water by theponding method at different ages (16h, 1, 2, 3, 7 and 28 days) for a period of 6, 18 and 36 (analysispending) months. The following properties were measured and compared with unexposed specimens:compressive strength, water and oxygen permeability, pore size distribution, migration coefficient DNT492and chloride profiles. After 6 and 18 months ponding, lower chloride contents were measured for thespecimens exposed to sea water after 28 days curing compared to those exposed at early ages.However, this difference significantly decreases within a small depth from the exposed surface. Also themigration coefficient DNT492 decreases significantly with the increase of the age of the concrete. Withregards to water and oxygen permeability, no significant differences were found. In this paper, a summaryof all these works is presented.Apart from this laboratory analysis, real scale tests were performed at site with the aim to increasedurability by the addition of nanosilica particles. The characterization of these real scale tests are alsodescribed and discussed in this paper.

sted, utgiver, år, opplag, sider
Institute of Australia , 2015. s. 894-903
Emneord [en]
concrete, caissons, durability, chlorides, nanosilica
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-378ISBN: 978-1-943847-70-9 (digital)OAI: oai:DiVA.org:ri-378DiVA, id: diva2:939536
Konferanse
27th Biennial National Conference of the Concrete Institute of Australia in conjunction with the 69th RILEM Week "Construction Innovations, Research into Practice", August 30 - September 2, 2015, Melbourne, Australia
Tilgjengelig fra: 2016-06-20 Laget: 2016-06-20 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Proceedings

Person

Mueller, UrsMalaga, Katarina

Søk i DiVA

Av forfatter/redaktør
Mueller, UrsMalaga, Katarina
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 353 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0