Towards a Traceable Calibration of Medium Voltage Transformers up to 150 kHz
LNE Laboratoire National de Métrologie et d’Essais, France.
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-5044-8266
FFII Fundación para el Fomento de la Innovación Industrial, Spain.
Università degli Studi della Campania “Luigi Vanvitelli”, Italy.
Vise andre og tillknytning
2025 (engelsk)Inngår i: EPJ Web of Conferences, EDP Sciences , 2025, Vol. 323, artikkel-id 12077Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The increasing integration of power electronics and renewable energy sources in modern electrical grids has introduced new challenges in medium voltage transformer calibration, particularly in the frequency range from 9 kHz to 150 kHz. Accurate and traceable calibration methods are essential to ensure reliable voltage measurement in electrical grids, where power quality and compliance with IEC 61869-1:2024 standards are critical. This study presents advancements in the development of traceable calibration techniques for medium voltage transformers operating within this frequency range. The approach includes the design of generators capable of simulating real world grid disturbances and the establishment of reference measurement systems at National Metrology Institutes. The study further explores generator configurations, such as parallel and series source arrangements, to extend calibration capabilities beyond existing limits. The proposed calibration methodology incorporates precision voltage dividers with high resolution, filtering and amplification techniques, and advanced data acquisition methods to achieve measurement uncertainties below 0.01% for fundamental components and between 0.2 % and 1 % for harmonic components. A key challenge is the ability to measure a fundamental voltage as high as 50 kV while superimposing harmonics with amplitudes as low as 5 V in the 9 kHz to 150 kHz range. These developments aim to enhance power system reliability, improve voltage measurement accuracy, and support the transition to more efficient and resilient electrical grids. The presented results lay the foundation for future calibration services. © The Authors, published by EDP Sciences.

sted, utgiver, år, opplag, sider
EDP Sciences , 2025. Vol. 323, artikkel-id 12077
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-78609DOI: 10.1051/epjconf/202532312007Scopus ID: 2-s2.0-105004026449OAI: oai:DiVA.org:ri-78609DiVA, id: diva2:1965455
Konferanse
22nd International Metrology Congress, CIM 2025Lyon11 March 2025through 14 March 2025
Tilgjengelig fra: 2025-06-09 Laget: 2025-06-09 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Elg, Alf Peter

Søk i DiVA

Av forfatter/redaktør
Elg, Alf Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 55 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0