Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of the applicability of GARDskin to predict skin sensitizers in extracts from medical device materials
SenzaGen AB, Sweden.
SenzaGen AB, Sweden.
SenzaGen AB, Sweden.
RISE Research Institutes of Sweden, Material och produktion, Metodik, textil och medicinteknik.ORCID-id: 0000-0002-9377-8924
Vise andre og tillknytning
2024 (engelsk)Inngår i: Frontiers in Toxicology, E-ISSN 2673-3080, Vol. 6, artikkel-id 1320367Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Biocompatibility testing of medical devices is governed by the ISO 10993 series of standards and includes evaluation of skin sensitization potential of the final product. A majority of all medical devices are tested using in vivo methods, largely due to the lack of in vitro methods validated within the applicability domain of solid materials. The GARDskin method for assessment of chemical skin sensitizers is a validated method included in the OECD Test Guideline 442E, based on evaluation of transcriptional patterns of an endpoint-specific genomic biomarker signature in a dendritic cell-like cell, following test chemical exposure. The current study aimed to evaluate the applicability of GARDskin for the purpose of testing solid materials by incorporation of extraction procedures described in ISO 10993-12:2021, as well as to demonstrate the functionality of the proposed protocols, by testing of custom-made materials spiked with sensitizing agents. It was shown that GARDskin is compatible with both polar and non-polar extraction vehicles frequently used for the purpose of medical device biological testing. Further, exploring three different material types spiked with up to four different sensitizing agents, as well as three unspiked control materials and commercial reference products, it was shown that the method correctly classified all evaluated test materials. Taken together, the data presented suggest that GARDskin may constitute a valid alternative to in vivo experimentation for the purpose of skin sensitization assessment of medical devices. 

sted, utgiver, år, opplag, sider
Frontiers Media SA , 2024. Vol. 6, artikkel-id 1320367
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-73244DOI: 10.3389/ftox.2024.1320367Scopus ID: 2-s2.0-85192257079OAI: oai:DiVA.org:ri-73244DiVA, id: diva2:1860372
Merknad

 The reported study was funded in its entirety by SenzaGen AB.

Tilgjengelig fra: 2024-05-24 Laget: 2024-05-24 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

fulltext(792 kB)216 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 792 kBChecksum SHA-512
cb7daa8f77aaac97c91b26a2d51645ea7282f4b7c4bbeb253192be6bd622b78ac9c094d3da59f0420ae1070a5865f9a82810837ade43db359d7da540e79bfbde
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Berglin, MattiasPedersen, Emma

Søk i DiVA

Av forfatter/redaktør
Berglin, MattiasPedersen, Emma
Av organisasjonen
I samme tidsskrift
Frontiers in Toxicology

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 217 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 278 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0