Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
An Invar-based dual Fabry-Perot cavity refractometer for assessment of pressure with a pressure independent uncertainty in the sub-mPa region
Umeå University, Sweden.
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik. Umeå University, Sweden.ORCID-id: 0000-0002-3261-9903
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-9068-6031
Umeå University, Sweden.
2023 (engelsk)Inngår i: Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics, ISSN 2166-2746, E-ISSN 2166-2754, Vol. 41, nr 6, artikkel-id 064206Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

An updated version of an Invar-based dual Fabry-Perot cavity refractometer utilizing the gas modulation methodology has been characterized with regard to its ability to assess gas pressure in the low pressure regime, defined as the regime in which the instrumentation is mainly limited by the constant term a in the [ ( a ) 2 + ( b × P ) 2 ] 1 / 2 expression for the uncertainty. It is first concluded that this ability is predominantly limited by three entities, viz., the empty cavity repeatability, the residual gas pressures in the evacuated (measurement) cavity, and the contamination of the gas residing in the measurement cavity that originates from leaks and outgassing. We then present and utilize methods to separately estimate the uncertainty of the updated refractometer from these entities. It was found that, when utilizing gas modulation cycles of 100 s and when addressing nitrogen, the system can assess pressure in the low pressure regime with an expanded uncertainty ( k = 2 ) of 0.75 mPa, mainly limited by the empty cavity repeatability and outgassing of hydrogen. This is more than 1 order of magnitude below the previously assessed low pressure performance of the instrumentation.

sted, utgiver, år, opplag, sider
AVS Science and Technology Society , 2023. Vol. 41, nr 6, artikkel-id 064206
Emneord [en]
Fabry-Perot interferometers; Fiber optic sensors; Refractometers; Uncertainty analysis; Fabry-Perot cavity; Gas pressures; Low pressures; Modulation cycles; Orders of magnitude; Performance; Pressure regime; Residual gas pressure; Uncertainty; Gases
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-69281DOI: 10.1116/6.0003149Scopus ID: 2-s2.0-85180985439OAI: oai:DiVA.org:ri-69281DiVA, id: diva2:1826252
Merknad

This work has received funding from the European Partnership on Metrology (MQB-Pascal, 22IEM04) and co-financed from the European Union’s Horizon Europe Research and Innovation Programme and by the Participating States. It has also been supported by Vetenskapsrådet (VR) (2020-05105) and the Vinnova Metrology Programme (2018-04570).

Tilgjengelig fra: 2024-01-11 Laget: 2024-01-11 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Zakrisson, JohanZelan, Martin

Søk i DiVA

Av forfatter/redaktør
Zakrisson, JohanZelan, Martin
Av organisasjonen
I samme tidsskrift
Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 129 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.49.0