Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
PERFORMANCE OF PASSIVE PROTECTION OF CROSS LAMINATED TIMBER DURING STANDARD FURNACE TESTS AND NATURAL FIRES
CERIB Fire Testing Centre, France.
University of Edinburgh, UK.
University of Edinburgh, UK.
University of Bordeaux, France.
Vise andre og tillknytning
2023 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper presents the results of an experimental campaign designed to compare and understand the performance of passive protection under exposure to standard furnace tests and natural fires. As part of this campaign, five natural fire experiments were performed with partially protected cross-laminated timber (CLT) compartments under a range of ventilation conditions. In all the tests, only one side wall was left completely unprotected, and all other timber surfaces were protected with either two layers of 18 mm standard gypsum boards (GB) or two layers of 25 mm standard GBs. The structural CLT ceilings were subjected to a superimposed dead load of 1.35 kN/m² during the natural fire tests, and the fire load was (on average) 950 MJ/m²; chosen to represent the Eurocode 1991-1-2 characteristic value for dwellings. The performance of the passive protection was mainly evaluated with regards to the time to reach a protected timber surface temperature of 250°C. The testing confirms that the resulting fire protection performance of a given gypsum board layout depends on the ventilation conditions of the fire compartment, with more severe (and closest to ISO testing) outcomes when testing under ventilation-controlled scenarios. This paper provides data that sheds light on the co-dependency of the passive protection design and compartment fire dynamics and underlines the importance of considering the safety objectives of a building when defining the performance criteria of its structural elements.

sted, utgiver, år, opplag, sider
2023. s. 1839-1847
Emneord [en]
Fire protection, Gypsum Plasterboard, Mass timber, Cross laminated timber, Natural fire
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-66207DOI: 10.52202/069179-0243OAI: oai:DiVA.org:ri-66207DiVA, id: diva2:1798810
Konferanse
WCTE2023 World Congerence on Timber Engineering 2023. Oslo, Norway
Tilgjengelig fra: 2023-09-20 Laget: 2023-09-20 Sist oppdatert: 2025-09-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstFull text

Person

McNamee, Robert

Søk i DiVA

Av forfatter/redaktør
McNamee, Robert
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 69 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0