Abstract [en]
Magnetic zero-flux current transformers are widely utilized to measure AC and DC electrical currents. To improve the AC characteristics between 10 Hz and 100 kHz, a method is proposed to evaluate adjustments in the circuitry; increase of the amplification in the AC feed-back circuit and introduction of an external coaxial read-out shunt resistor. The method is generally applicable and includes a coaxial current path within the entire reference system and traceability to national standards. The AC working range is extended from about 1 kHz to about 3 kHz. Outside the nominal AC working range, the scale factor variation is reduced from 45 % to 3.5% and the phase angle error offset changes from ca 5.8 μs to below 0.3 μs.
sted, utgiver, år, opplag, sider
2014. s. 618-619, artikkel-id 6898537
Emneord [en]
AC current, current transformer, frequency response, measurement technique, traceability, zero-flux, AC currents, Measurement techniques, Measuring systems, Electric instrument transformers
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-32457DOI: 10.1109/CPEM.2014.6898537Scopus ID: 2-s2.0-84907895873ISBN: 9781479952052 (tryckt)OAI: oai:DiVA.org:ri-32457DiVA, id: diva2:1154720
Konferanse
29th Conference on Precision Electromagnetic Measurements, CPEM 2014, 24 August 2014 through 29 August 2014
2017-11-032017-11-032025-09-23bibliografisk kontrollert