Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
Link to record
Permanent link

Direct link
Publications (10 of 42) Show all publications
Kampik, M., Grzenik, M., Lippert, T., Rydler, K.-E., Tarasso, V. & Trinchera, B. (2021). Comparison of a Thermal AC Voltage Standard in the 1 MHz to 30 MHz Frequency Range. IEEE Transactions on Instrumentation and Measurement, 70, Article ID 1500508.
Open this publication in new window or tab >>Comparison of a Thermal AC Voltage Standard in the 1 MHz to 30 MHz Frequency Range
Show others...
2021 (English)In: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 70, article id 1500508Article in journal (Refereed) Published
Abstract [en]

The paper presents results of a comparison of a travelling AC voltage standard, which was a fused-silica NIST planar multijunction thin-film thermal converter (PMJTC). The AC-DC voltage transfer difference of the standard was measured at 2 V and selected frequencies from 1 MHz to 30 MHz against primary thermal AC voltage standards at SUT, INRiM, RISE and Trescal.

Keywords
Standards, Voltage measurement, Frequency measurement, Uncertainty, Connectors, Measurement uncertainty, Temperature measurement, measurement standards, thermal converter, AC-DC transfer, AC-DC transfer difference, key comparison
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-48273 (URN)10.1109/TIM.2020.3007296 (DOI)
Available from: 2020-09-04 Created: 2020-09-04 Last updated: 2025-09-23Bibliographically approved
Rydler, K.-E., Tranefors, K., Bergman, A., Nieminen, T. & Larsson, B. (2019). A calorimetric measuring system for measurement of loss in high voltage cable conductors. In: Jean-Michel LEQUEUX (Ed.), JiCable 2019, 10th international conference on insulated power cables, Versailles,France. June, 2019.: . Paper presented at JiCable 2019.
Open this publication in new window or tab >>A calorimetric measuring system for measurement of loss in high voltage cable conductors
Show others...
2019 (English)In: JiCable 2019, 10th international conference on insulated power cables, Versailles,France. June, 2019. / [ed] Jean-Michel LEQUEUX, 2019Conference paper, Published paper (Other academic)
Abstract [en]

A calorimetric measuring system for measuring the ratio between AC and DC resistance, RAC/RDC, of high voltage power cable conductors has been designed and constructed. An uncertainty analysis predicts that the ratio RAC/RDC at 90°C of a 2500 mm2 cable of low loss design can be measured with an uncertainty of 1,0%. But the uncertainty of an actual measurement was larger due to unresolved sources of uncertainty.

Keywords
cable, cables, power cable, conductor resistance, low loss, cable connection, High voltage AC cable, Power loss measurement, AC resistance, skin effect, calorimeter, measuring system, uncertainty analysis, kabel, högspänning, ledarresistans, kraftkabel, ledaranslutning
National Category
Infrastructure Engineering
Identifiers
urn:nbn:se:ri:diva-40748 (URN)
Conference
JiCable 2019
Funder
European Metrology Programme for Innovation and Research (EMPIR), ElPow
Note

The work reported here has received support from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme.

Available from: 2019-11-06 Created: 2019-11-06 Last updated: 2025-09-23Bibliographically approved
Bergsten, T. & Rydler, K.-E. (2019). Realization of Absolute Phase and AC Resistance of Current Shunts by Ratio Measurements. IEEE Transactions on Instrumentation and Measurement, 68(6), 2041-2046
Open this publication in new window or tab >>Realization of Absolute Phase and AC Resistance of Current Shunts by Ratio Measurements
2019 (English)In: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 68, no 6, p. 2041-2046Article in journal (Refereed) Published
Abstract [en]

This paper presents a simplified method for realizing absolute phase and ac resistance for current shunts using only impedance ratio measurements. The method is based on three geometrically identical current shunts with different resistances, but with the same inductance, capacitance, and ac-dc resistance change of resistance at ac compared to dc). We demonstrate how the inductance, capacitance, and ac resistance can be calculated from the complex impedance ratio measurements, therefore realizing absolute current shunt impedance. The method gives competitive uncertainties of around 200 μΩ/Ω for amplitude and 400 μrad for phase at 1 MHz in the 1-Ω range.

Keywords
Impedance, Resistance, Current measurement, Impedance measurement, Electrical resistance measurement, Capacitance, Inductance, current shunt, measurement standards, phase measurement, resistance.
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-38595 (URN)10.1109/TIM.2018.2882927 (DOI)2-s2.0-85065873080 (Scopus ID)
Available from: 2019-05-09 Created: 2019-05-09 Last updated: 2025-09-23Bibliographically approved
Rydler, K.-E., Bergsten, T. & Eklund, G. (2018). A Method for Realisation of Inductance and Quality Factor to 1 MHz. In: CPEM 2018 - Conference on Precision Electromagnetic Measurements: . Paper presented at 2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018.
Open this publication in new window or tab >>A Method for Realisation of Inductance and Quality Factor to 1 MHz
2018 (English)In: CPEM 2018 - Conference on Precision Electromagnetic Measurements, 2018Conference paper, Published paper (Refereed)
Abstract [en]

This paper describes a method for realisation of inductance and quality factor to high frequencies by determining the frequency response of gain-and phase-error of an inductance meter using two coils made of a single copper wire. As a starting point a traceable calibration of inductance at 1 kHz is used

Keywords
Impedance measurement, inductance, measurement, measurement standards, measurement techniques, Q measurement, resistance, Electric resistance, Frequency response, Gain and phase error, High frequency HF, Q measurements, Quality factors, Traceable calibration
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-36599 (URN)10.1109/CPEM.2018.8500813 (DOI)2-s2.0-85056995744 (Scopus ID)9781538609736 (ISBN)
Conference
2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018
Available from: 2018-12-17 Created: 2018-12-17 Last updated: 2025-09-23Bibliographically approved
Bergsten, T. & Rydler, K.-E. (2018). Realisation of Absolute Phase and Ac Resistance of Current Shunts by Ratio Measurements. In: CPEM 2018 - Conference on Precision Electromagnetic Measurements: . Paper presented at 2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018.
Open this publication in new window or tab >>Realisation of Absolute Phase and Ac Resistance of Current Shunts by Ratio Measurements
2018 (English)In: CPEM 2018 - Conference on Precision Electromagnetic Measurements, 2018Conference paper, Published paper (Refereed)
Abstract [en]

This article presents a method for realising absolute phase and ac resistance for current shunts using only impedance ratio measurements. The method is based on three geometrically identical current shunts with different resistances, but with the same inductance, capacitance and ac resistance (change of resistance at ac compared to dc), We demonstrate how the inductance, capacitance and ac resistance can be calculated from the complex impedance ratio measurements, thereby realising absolute current shunt impedance. This method simplifies the procedure of current shunt calibration, since the same impedance ratio setup which is used to compare a shunt to a reference shunt, is used to realise the impedance of the starting reference shunt.

Keywords
Capacitance, current shunt, impedance measurement, inductance, measurement standards, phase measurement, resistance, Electric resistance, Electric resistance measurement, Absolute phase, AC resistance, Complex impedance, Current shunts, Impedance ratios
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-36601 (URN)10.1109/CPEM.2018.8500935 (DOI)2-s2.0-85057022638 (Scopus ID)9781538609736 (ISBN)
Conference
2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018
Available from: 2018-12-17 Created: 2018-12-17 Last updated: 2025-09-23Bibliographically approved
Kampik, M., Grzenik, M. L., Lippert, T., Rydler, K.-E. & Tarasso, V. (2018). Trilateral Comparison of a Planar Thin-Film Thermal AC Voltage Standard in Frequency Range 1 MHz-30 MHz. In: CPEM 2018 - Conference on Precision Electromagnetic Measurements: . Paper presented at 2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018. Institute of Electrical and Electronics Engineers Inc., Article ID 8501130.
Open this publication in new window or tab >>Trilateral Comparison of a Planar Thin-Film Thermal AC Voltage Standard in Frequency Range 1 MHz-30 MHz
Show others...
2018 (English)In: CPEM 2018 - Conference on Precision Electromagnetic Measurements, Institute of Electrical and Electronics Engineers Inc. , 2018, article id 8501130Conference paper, Published paper (Refereed)
Abstract [en]

The paper presents results of a trilateral comparison of a travelling AC voltage standard, which was a fused-silica NIST planar multijunction thin-film thermal converter. The AC-DC voltage transfer difference of the standard was measured at 2 V and selected frequencies from 1 MHz to 30 MHz against primary thermal AC voltage standards at SUT, RISE and Trescal.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers Inc., 2018
Keywords
AC-DC transfer, AC-DC transfer difference, key comparison, measurement standards, thermal converter, Electronic equipment, Fused silica, Thin films, Thermal converters, Rectifying circuits
National Category
Engineering and Technology
Identifiers
urn:nbn:se:ri:diva-37281 (URN)10.1109/CPEM.2018.8501130 (DOI)2-s2.0-85056235749 (Scopus ID)9781538609736 (ISBN)
Conference
2018 Conference on Precision Electromagnetic Measurements, CPEM 2018, 8 July 2018 through 13 July 2018
Available from: 2019-01-18 Created: 2019-01-18 Last updated: 2025-09-23Bibliographically approved
Eklund, G., Bergsten, T. & Rydler, K.-E. (2016). A low frequency Josephson impedance bridge. In: CPEM 2016 - Conference on Precision Electromagnetic Measurements, Conference Digest: . Paper presented at 2016 Conference on Precision Electromagnetic Measurements, CPEM 2016, 10 July 2016 through 15 July 2016.
Open this publication in new window or tab >>A low frequency Josephson impedance bridge
2016 (English)In: CPEM 2016 - Conference on Precision Electromagnetic Measurements, Conference Digest, 2016Conference paper, Published paper (Refereed)
Abstract [en]

We describe a low frequency Josephson impedance bridge and the measurement methods. The bridge is useable below 400 Hz and is based on two programmable Josephson voltage standards. Measurements of 1:1, 1:2 and 1:10 capacitance ratio have been performed and compared with ratio measurements of an inductive voltage divider bridge. © 2016 IEEE.

Keywords
Impedance bridge, Josephson array, Josephson impedance bridge, Josephson voltage standard, Capacitance, Josephson junction devices, Voltage dividers, Voltage measurement, Capacitance ratio, Impedance bridges, Inductive voltage divider, Josephson voltage standards, Measurement methods, Measurements of, Programmable Josephson voltage standard, Electric measuring bridges
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-27625 (URN)10.1109/CPEM.2016.7540509 (DOI)2-s2.0-84986272615 (Scopus ID)9781467391344 (ISBN)
Conference
2016 Conference on Precision Electromagnetic Measurements, CPEM 2016, 10 July 2016 through 15 July 2016
Note

References: Behr, R., Kieler, O., Kohlmann, J., Möller, F., Palafox, L., Devolopment and metrological applications of Josephson arrays at PTB (2012) Meas.Sci.Technol, 23 (12), p. 124002; Eklund, G., Bergsten, T., Tarasso, V., Rydler, K.-E., Determination of transition error corrections for low frequency stepwise-Approximated josephson sine waves (2011) IEEE Trans. Instrum. Meas, 60 (7), pp. 2399-2403; Lee, J., Schurr, J., Nissilä, J., Palafox, L., Behr, R., The Josephson two-Terminal-pair impedance bridge (2010) Metrologia, 47, pp. 453-459; Eklund, G., Bergsten, T., Tarasso, V., Rydler, K.-E., Progress towards an Impedance Bridge using two Programmable Josephson Voltage Standards (2014) CPEM 2014 Conference Digest, Rio de Janeiro, Brazil, , August; Palafox, L., Behr, R., Schurr, J., Kibble, B.P., Precision 10:1 capacitance ratio measurement using a josephson impedance bridge (2014) CPEM 2014 Conference Digest, Rio de Janeiro, Brazil, , August; Eklund, G., Bergsten, T., Hagen, T., Palafox, L., Behr, R., A comparison of the josephson impedance bridges of PTB and SP CPEM 2016 Conference Digest

Available from: 2016-12-22 Created: 2016-12-21 Last updated: 2025-09-23Bibliographically approved
Bergsten, T., Tarasso, V. & Rydler, K.-E. (2016). An electrical power reference system Up to 1 MHz. In: Conference on Precision Electromagnetic Measurements (CPEM 2016): . Paper presented at Conference on Precision Electromagnetic Measurements 2016.
Open this publication in new window or tab >>An electrical power reference system Up to 1 MHz
2016 (English)In: Conference on Precision Electromagnetic Measurements (CPEM 2016), 2016Conference paper, Published paper (Refereed)
Abstract [en]

We present a reference system for calibration of electrical power at frequencies up to 1 MHz. The system consists of several components and we have developed methods of calibrating the components in order to ensure traceability to the SI units. The reference system is designed for steady state sinusoidal signals and gives a preliminary uncertainty of 50 μW/VA at frequencies up to 1 kHz, and 10 mW/VA at 1 MHz.

Keywords
Power measurement, Phase measurement, Measurement standards, Voltage measurement, Current measurement Signal sampling
National Category
Engineering and Technology
Identifiers
urn:nbn:se:ri:diva-48293 (URN)10.1109/CPEM.2016.7540733 (DOI)
Conference
Conference on Precision Electromagnetic Measurements 2016
Available from: 2020-09-08 Created: 2020-09-08 Last updated: 2025-09-23Bibliographically approved
Svensson, S., Rydler, K.-E. & Tarasso, V. (2016). Upgrade of accuracy and traceability the SP Sampling Wattmeter. In: 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016): . Paper presented at 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016), July 10-15, 2016, Ottawa, Canada.
Open this publication in new window or tab >>Upgrade of accuracy and traceability the SP Sampling Wattmeter
2016 (English)In: 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016), 2016Conference paper, Published paper (Refereed)
Abstract [en]

The Digital Sampling Wattmeter of SP has been upgraded. New resistive shunts and dividers are built, with lower temperature coefficient and less power dependence. The aperture time of the samplers are increased. The calibration methods are also upgraded by use of more direct AC/DC calibration. The goal of 10 μW/W seems to be within reach.

Keywords
electrical power measurement, Measurement, measurement standards, measurement techniques, measurement uncertainty, precision measurements, traceability, uncertainty, Calibration, Measurements, Wattmeters, Electrical power measurements, Precision measurement, Uncertainty analysis
National Category
Natural Sciences
Identifiers
urn:nbn:se:ri:diva-27628 (URN)10.1109/CPEM.2016.7540707 (DOI)2-s2.0-84986249786 (Scopus ID)978-1-4673-9134-4 (ISBN)
Conference
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016), July 10-15, 2016, Ottawa, Canada
Note

References: Svensson, S., Rydler, K.-E., A measuring system for calibration of power analyzers (1994) Precision Electromagnetic Measurements, pp. 299-300. , Digest., 1994 Conference on Year, 1994 Pages; Svensson, S., A wattmeter standard for the audio frequency range (1999) Instrumentation and Measurement IEEE Transactions on Year, 48 (2), pp. 431-433; Svensson, S., Rydler, K.-E., Tarasso, V., Improved model and phase-Angle verification of current shunts for ac and power measurements (2004) Precision Electromagnetic Measurements Digest 2004 Conference on Year, pp. 82-83; Rydler, K.-E., Svensson, S., Tarasso, V., Voltage dividers with low phase angle errors for a wideband power measuring system (2002) Precision Electromagnetic Measurements 2002 Conference Digest 2002 Conference on Year, pp. 382-383; Espel, P., Poletaeff, A., Bounouh, A., Static characterization of analog-To-digital converter (2009) Fundamental and Applied Metrology: XIX IMEKO World Congress, , September 6-11, 2009, Lisbon, Portugal; Svensson, S., Juvik, J.I., Comparison on sampling wattmeter strategies (2006) Conference on Precision Electromagnetic Measurements, 2006

Available from: 2016-12-22 Created: 2016-12-21 Last updated: 2025-09-23Bibliographically approved
Bergsten, T., Eklund, G., Tarasso, V. & Rydler, K.-E. (2015). An Active Filter for Delta-Sigma-Modulated Josephson Waveforms. IEEE Transactions on Instrumentation and Measurement, 64(6), 1559-1563
Open this publication in new window or tab >>An Active Filter for Delta-Sigma-Modulated Josephson Waveforms
2015 (English)In: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 64, no 6, p. 1559-1563Article in journal (Refereed) Published
Abstract [en]

We present the design and electrical characteristics of an active low-pass filter. It will be used in a reference waveform source based on a programmable Josephson voltage standard with multilevel delta-sigma modulation to generate accurate and spectrally pure arbitrary waveforms. The filter has a fifth-order Butterworth characteristic with high input impedance, low distortion, high stopband attenuation, and stable passband performance, including dc.

Keywords
Active filters, Butterworth filters, Delta-sigma modulation, Low-pass filters, Josephson voltage standards
National Category
Engineering and Technology
Identifiers
urn:nbn:se:ri:diva-48296 (URN)10.1109/TIM.2015.2418454 (DOI)
Available from: 2020-09-08 Created: 2020-09-08 Last updated: 2025-09-23Bibliographically approved