Endre søk
Link to record
Permanent link

Direct link
Publikasjoner (2 av 2) Visa alla publikasjoner
Jonas, S., Kumme, R., Falk, T., Davood, M., Miha, H., Wozniak, M., . . . Gerber, S. (2023). Strategy report for offering traceable calibration for testing machines under continuous and dynamic forces.
Åpne denne publikasjonen i ny fane eller vindu >>Strategy report for offering traceable calibration for testing machines under continuous and dynamic forces
Vise andre…
2023 (engelsk)Rapport (Annet vitenskapelig)
HSV kategori
Identifikatorer
urn:nbn:se:ri:diva-71212 (URN)10.5281/zenodo.7866831 (DOI)
Tilgjengelig fra: 2024-01-24 Laget: 2024-01-24 Sist oppdatert: 2025-09-23bibliografisk kontrollert
Amer, E., Wozniak, M., Jönsson, G. & Arrhén, F. (2021). Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration. Sensors, 21(13), Article ID 4470.
Åpne denne publikasjonen i ny fane eller vindu >>Evaluation of Shock Tube Retrofitted with Fast-Opening Valve for Dynamic Pressure Calibration
2021 (engelsk)Inngår i: Sensors, E-ISSN 1424-8220, Vol. 21, nr 13, artikkel-id 4470Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Accurate dynamic pressure measurements are increasingly important. While traceability is lacking, several National Metrology Institutes (NMIs) and calibration laboratories are currently establishing calibration capacities. Shock tubes generating pressure steps with rise times below 1 µs are highly suitable as standards for dynamic pressures in gas. In this work, we present the results from applying a fast-opening valve (FOV) to a shock tube designed for dynamic pressure measurements. We compare the performance of the shock tube when operated with conventional single and double diaphragms and when operated using an FOV. Different aspects are addressed: shock-wave formation, repeatability in amplitude of the realized pressure steps, the assessment of the required driver pressure for realizing nominal pressure steps, and economy. The results show that using the FOV has many advantages compared to the diaphragm: better repeatability, eight times faster to operate, and enables automation of the test sequences.

sted, utgiver, år, opplag, sider
MDPI, 2021
Emneord
dynamic pressure, shock tube, fast-opening valve, repeatability
HSV kategori
Identifikatorer
urn:nbn:se:ri:diva-55130 (URN)10.3390/s21134470 (DOI)
Tilgjengelig fra: 2021-07-02 Laget: 2021-07-02 Sist oppdatert: 2025-09-23bibliografisk kontrollert
Organisasjoner
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0002-9144-5851