A multiphysics Simulation-Driven Design approach has been undertaken to augment the OCP Leopard Server thermal management and heat recovery hardware with the Nexalus hybrid liquid-cooled sealed server technology. Independent testing at the RISE Research Institute of Sweden has proven up to 98% heat recovery is achievable at water temperatures up to and exceeding 65°C. The improved design could maintain the elevated water temperature over a range of CPU workloads, ranging from 8% to 75%. Importantly, the design solution achieves this within an architecture that is IOU in height, half that of the original stock 20U server, potentially doubling the compute density of a rack.
Cooling of IT equipment consumes a large proportion of a modern data centre’s energy budget and is therefore an important target for optimal control. This study analyses a scaled down system of six servers with cooling fans by implementing a minimal data driven time-series model in TensorFlow/Keras, a modern software package popular for deep learning. The model is inspired by the physical laws of heat exchange, but with all parameters obtained by optimisation. It is encoded as a customised Recurrent Neural Network and exposed to the time-series data via n-step Prediction Error Minimisation (PEM). The thus obtained Digital Twin of the physical system is then used directly to construct a Model Predictive Control (MPC) type regulator that executes in real time. The MPC is then compared in simulation with a self-tuning PID controller that adjust its parameters on-line by gradient descent.
Low latency requirements are expected to increase with 5G telecommunications driving data and compute to EDGE data centers located in cities near to end users. This article presents a testbed for such data centers that has been built at RISE ICE Datacenter in northern Sweden in order to perform full stack experiments on load balancing, cooling, micro-grid interactions and the use of renewable energy sources. This system is described with details on both hardware components and software implementations used for data collection and control. A use case for off-grid operation is presented to demonstrate how the test lab can be used for experiments on edge data center design, control and autonomous operation. © 2020 Author.
This report investigates the problem of where to place computation workload in an edge-cloud network topology considering the trade-off between the location specific cost of computation and data communication.
This article investigates the problem of where to place the computation workload in an edge-cloud network topology considering the trade-off between the location-specific cost of computation and data communication. For this purpose, a Monte Carlo simulation model is defined that accounts for different workload types, their distribution across time and location, as well as correlation structure. Results confirm and quantify the intuition that optimization can be achieved by distributing a part of cloud computation to make efficient use of resources in an edge data center network, with operational energy savings of 4â6% and up to 50% reduction in its claim for cloud capacity.
Purpose – This aim of this work is to investigate different modelling approaches for air-cooled data centres. The study employs three computational methods, which are based on finite element, finite volume and lattice Boltzmann methods and which are respectively implemented via commercial Multiphysics software, opensource computational fluid dynamics code and graphical processing unit-based code developed by the authors. The results focus on comparison of the three methods, all of which include models for turbulence, when applied to two rows of datacom racks with cool air supplied via an underfloor plenum. Design/methodology/approach – This paper studies thermal airflows in a data centre by applying different numerical simulation techniques that are able to analyse the thermal airflow distribution for a simplified layout of datacom racks in the presence of a computer room air conditioner. Findings – Good quantitative agreement between the three methods is seen in terms of the inlet temperatures to the datacom equipment. The computational methods are contrasted in terms of application to thermal management of data centres. Originality/value – The work demonstrates how the different simulation techniques applied to thermal management of airflow in a data centre can provide valuable design and operational understanding. Basing the analysis on three very different computational approaches is new and would offer an informed understanding of their potential for a class of problems.
Data centers are complex systems that require sophisticated operational management approaches to provide the availability of digital services against the backdrop of cost and energy efficiency. To achieve this, data center telemetry data is required since, as is commonly said it is not possible to manage what cannot be measured. This paper details how it is possible to construct the key data center infrastructure management (DCIM) elements of monitoring and measuring by a combination of available opensource software tools that permit both scalability and an environment where analytics can be employed on the data center operation, which can offer relevant insight into energy efficient operational practices.
Across cultures, people associate colours with emotions. Here, we test the hypothesis that one driver of this cross-modal correspondence is the physical environment we live in. We focus on a prime example – the association of yellow with joy, – which conceivably arises because yellow is reminiscent of life-sustaining sunshine and pleasant weather. If so, this association should be especially strong in countries where sunny weather is a rare occurrence. We analysed yellow-joy associations of 6625 participants from 55 countries to investigate how yellow-joy associations varied geographically, climatologically, and seasonally. We assessed the distance to the equator, sunshine, precipitation, and daytime hours. Consistent with our hypotheses, participants who live further away from the equator and in rainier countries are more likely to associate yellow with joy. We did not find associations with seasonal variations. Our findings support a role for the physical environment in shaping the affective meaning of colour.
The energy sector is essential in the transition to a more sustainable future, and renewable energies will play a key role in achieving this. It is also a sector in which the circular economy presents an opportunity for the utilisation of other resources and residual energy flows. This study examines the environmental and social performance of innovative energy technologies (which contribute to the circularity of resources) implemented in a demonstrator site in Luleå (Sweden). The demo-site collected excess heat from a data centre to cogenerate energy, combining the waste heat with fuel cells that use biogas derived from waste, meeting part of its electrical demand and supplying thermal energy to an existing district heating network. Following a cradle-to-gate approach, an environmental and a social life cycle assessment were developed to compare two scenarios: a baseline scenario reflecting current energy supply methods and the WEDISTRICT scenario, which considers the application of different renewable and circular technologies. The findings indicate that transitioning to renewable energy sources significantly reduces environmental impacts in seven of the eight assessed impact categories. Specifically, the study showed a 48% reduction in climate change impact per kWh generated. Additionally, the WEDISTRICT scenario, accounting for avoided burdens, prevented 0.21 kg CO2 eq per kWh auto-consumed. From the social perspective, the WEDISTRICT scenario demonstrated improvement in employment conditions within the worker and local community categories, product satisfaction within the society category, and fair competition within the value chain category. Projects like WEDISTRICT demonstrate the circularity options of the energy sector, the utilisation of resources and residual energy flows, and that these lead to environmental and social improvements throughout the entire life cycle, not just during the operation phase.
Electrohydrodynamic (EHD) air blowers are receiving increasing attention as a thermal management cooling solution to overcome the restrictions of traditional rotary cooling systems used in small-scale consumer electronics. In this work, the performance and flow pattern characteristics of miniature EHD air blowers are evaluated for practical convective heat transfer applications, based on device size, operating voltage and power, and generated flow rate. For a range of blower heights up to 10 mm, two-dimensional (2D) and three-dimensional (3D) numerical models of a wire-to-plane EHD channel configuration are developed and validated against previous experimental data. Investigation of the influence of blower sidewalls, based on width parameter, on flow characteristics reveals that the 2D simulations for short and wide blower domains are valid to predict the generated flow rates effectively compared to that obtained by the means of 3D simulations. An optimized combined EHD blower is developed as a flow-controlled cooling system in thermal management applications, which minimizes the required operating voltages for specified flow rates. Comparisons against commercial rotary blowers demonstrate that the miniature EHD blowers are more competitive as cooling solutions for compact applications and extended heated surfaces based on transduction efficiency, blower size, flow production of uniform velocity profile, and power consumption.
Electrohydrodynamic (EHD) air blowers are uniquely positioned to overcome the limitations of miniaturized mechanical fans in small-scale and consumer electronic devices. A novel cooling system design using optimized EHD blowers integrated with a plate-fin heat sink is presented and proposed for thin consumer electronics such as laptop applications. A three-dimensional (3D) numerical model is developed and validated to solve the coupled equations of EHD flow and conjugate heat transfer and predict the cooling performance of the integrated EHD system. For a range of heat sink heights from 6 to 12 mm, a parametric study is performed to investigate the influence of geometric parameters and operating conditions on the thermal performance of the EHD systems based on heat sink thermal resistance and the highest operating temperature. Numerical results demonstrate that the proposed EHD cooling system is able to provide effective cooling performance and maintain the temperature within the safe and typical operating range. Under a range of thermal design power (TDP) up to 30 W, trends of predicted operating temperatures show that the developed EHD cooling systems have great potential to compete with mechanical blowers in low-profile laptops with higher TDP, lower device height and reduced installation volume compared to a selected list of current standard laptops available commercially.
This paper analyzes the prospects of a holistic air-cooling strategy that enables synchronisation of data center facility fans and server fans to minimize data center energy use. Each server is equipped with a custom circuit board which controls the fans using a proportional, integral and derivative (PID) controller running on the servers operating system to maintain constant operating temperatures, irrespective of environmental conditions or workload. Experiments are carried out in a server wind tunnel which is controlled to mimic data center environmental conditions. The wind tunnel fan, humidifier and heater are controlled via separate PID controllers to maintain a prescribed pressure drop across the server with air entering at a defined temperature and humidity. The experiments demonstrate server operating temperatures which optimally trade off power losses versus server fan power, while examining the effect on the temperature difference, ∆T. Furthermore the results are theoretically applied to a direct fresh air cooled data center to obtain holistic sweet spots for the servers, revealing that the minimum energy use is already attained by factory control. Power consumption and Power Usage Effectiveness (PUE) are also compared, confirming that decreasing the PUE can increase the overall data center power consumption. Lastly the effect of decreased server inlet temperatures is examined showing that lower inlet temperatures can reduce both energy consumption and PUE.
Simulation tools for thermal management of datacenters help to improve layout of new builds or analyse thermalproblems in existing data centers. The development of LBMon remote GPUs as an approach for such simulations is discussedmaking use of VirtualGL and prioritised multi-threadedimplementations of an existing LBM code. The simulation isconfigured to model an existing and highly monitored test datacenter. Steady-state root mean square averages of measured andsimulated temperatures are compared showing good agreement.The full capability of this simulation approach is demonstratedwhen comparing rack temperatures against a time varyingworkload, which employs time-dependent boundary conditions.
Server power densities are foreseen to increase, and conventional air-cooling systems will struggle to cope with thermal demand. Single-phase immersion systems are a promising alternative to operate very intensive workload such as high-performance computing, cryptocurrencies mining or research activities. However, few companies deal with this kind of system and there is a lack of energy models that can reproduce an accurate analysis of the system behaviour. This study addresses the experimentation, data collection, and model validation of a single-phase immersion cooling system where 54 open compute project servers, each with a peak power of 400 Watts that are submerged and operated in a dielectric coolant. Results show the evolution of the thermal profile of the system under static and dynamic workloads, and it provides a correlation of server energy use under various system temperatures. The energy model is presented, validated against real data, and exploited to investigate the system response to different cooling conditions. In conclusion, the study demonstrates the validation of the energy model and supports the basis for further investigation. © 2023 The Authors