The current paper reports results from a preliminary study on PREGCYL™ NC R2HM-01 which is a carbon nanotube doped prepreg produced by Nanocyl. The work consisted of sample manufacturing in autoclave, microcopy analysis with XHR-SEM and mechanical testing. The mechanical testing consisted of tensile tests of unidirectional (in longitudinal direction) and cross-ply laminates. Test of unidirectional laminates showed that stiffness of the PREGCYL material is slightly higher than that of MTM55 composites (111GPa vs 102GPa). The results from tests of cross-ply laminates indicated that damage (transverse cracks) initiation is delayed in PREGCYL composites compare to the MTM55 material. Damage accumulation also seems to be slower in nano-doped composites.