Galvanic corrosion properties of steel in water saturated concrete
RISE, Swerea, Swerea KIMAB.
RISE, Swerea, Swerea KIMAB.
RISE, Swerea, Swerea KIMAB.
Lund University.
2015 (English)In: Materials and corrosion - Werkstoffe und Korrosion, ISSN 0947-5117, E-ISSN 1521-4176, Vol. 66, no 1, p. 67-75Article in journal (Refereed)
Abstract [en]

Aluminum-based sacrificial anodes were installed to reinforced concrete to stop ongoing corrosion in cooling water tunnels in a Swedish nuclear power plant. The steel rebars were also unintentionally connected to stainless steel water pumps. Therefore, the consumption rate of the sacrificial anodes was higher than predicted. An experimental and a field study were performed to assess if the steel rebar suffer from galvanic corrosion and if the stainless steel pumps are responsible alone for the high consumption rate. It was found from the experimental study that there is an increased risk of galvanic corrosion for steel rebar when the corrosion potential is raised to -200mV (SCE) for samples with 1% CL- by mass of cement and -500mV (SCE) for samples with 2% Cl- by mass of cement. The experimental results were compared with the corrosion potential measured in the cooling water tunnel where sacri ficial anodes were in use and not mounted at all. The cooling water tunnel without sacrificial anodes had generally more anodic corrosion potentials compared to the tunnel with anodes. The tunnel with anodes had also more anodic potentials closer to the stainless steel pumps than further away which means that the rebar is affected by the stainless steel pumps. However, the measured corrosion potentials in the tunnels were not as anodic as the potentials needed for high galvanic current measured in the experimental study. © 2013 Wiley-VCH Verlag GmbH & Co. KGaA.

Place, publisher, year, edition, pages
2015. Vol. 66, no 1, p. 67-75
Keywords [en]
Galvanic corrosion, Stainless steel, Steel reinforced concrete
National Category
Materials Engineering
Identifiers
URN: urn:nbn:se:ri:diva-12780DOI: 10.1002/maco.201307141Scopus ID: 2-s2.0-84920848908OAI: oai:DiVA.org:ri-12780DiVA, id: diva2:972973
Available from: 2016-09-22 Created: 2016-09-22 Last updated: 2017-11-21Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopushttp://onlinelibrary.wiley.com/doi/10.1002/maco.201307141/abstract
By organisation
Swerea KIMAB
In the same journal
Materials and corrosion - Werkstoffe und Korrosion
Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 57 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.4