Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ultrasound Doppler measurements inside a diaphragm valve using novel transducer technologies
Cape Peninsula University of Technology, South Africa.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SIK – Institutet för livsmedel och bioteknik.ORCID iD: 0000-0002-7856-2324
2014 (English)In: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, no 10, p. 105302-Article in journal (Refereed) Published
Abstract [en]

In this project, velocity profiles were measured in a diaphragm valve using an ultrasonic velocity profiling (UVP) technique. A non-Newtonian CMC model fluid was tested in this highly complex geometry and velocity profiles were measured at four different positions at the centre (contraction) of a specially manufactured 50% open diaphragm valve. The coordinates of the complex geometry and velocity magnitudes were analysed and compared to the bulk flow rate measured using an electromagnetic flow meter. Two different ultrasonic transducers (standard and delay line) were used and results were compared in order to assess velocity data close to wall interfaces as well as the accuracy and magnitude of measured velocities. The difference between calculated and measured flow rates was 32% when using the standard ultrasonic transducers. The error difference decreased to 18% when delay line transducers were introduced to the measurements. The velocity data obtained in the diaphragm valve showed a significant improvement close to the wall interfaces when using the delay line transducers. The main limitation when using delay line transducers is that beam refraction can significantly complicate measurements in a highly complex geometry such as a diaphragm valve. A new delay line transducer with no beam refraction could provide a solution. The introduction of delay line transducers showed that UVP can be used as a powerful tool for detailed flow behaviour measurements in complex geometries.

Place, publisher, year, edition, pages
2014. Vol. 25, no 10, p. 105302-
Keywords [en]
Food Engineering
Keywords [sv]
Livsmedelsteknik
National Category
Food Science
Identifiers
URN: urn:nbn:se:ri:diva-9272DOI: 10.1088/0957-0233/25/10/105302Scopus ID: 2-s2.0-84907153241OAI: oai:DiVA.org:ri-9272DiVA, id: diva2:967146
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2020-12-01Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Wiklund, Johan

Search in DiVA

By author/editor
Wiklund, Johan
By organisation
SIK – Institutet för livsmedel och bioteknik
In the same journal
Measurement science and technology
Food Science

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 27 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf