Behaviour of loaded cross-laminated timber wall elements in fire conditions
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Hållbar Samhällsbyggnad. Luleå University of Technology, Sweden.
University of Sassari, Italy.
University of Sassari, Italy.
University of Trieste, Italy.
Show others and affiliations
2015 (English)In: Fire technology, ISSN 0015-2684, E-ISSN 1572-8099, Vol. 51, no 6, p. 1341-1370Article in journal (Refereed) Published
Abstract [en]

Cross-laminated timber (CLT) is increasingly being used in medium-rise timber buildings for a number of reasons, such as rapidity of construction, cost effectiveness and robustness. Like for other building materials, verification of the load-bearing performance in fire conditions is an important issue. Experimental fire tests have been performed on loaded CLT wall elements at research institutes in Sweden and Italy. In total, three large-scale and four medium-scale tests have been carried out. The aim was to gain information about initially protected and unprotected elements, to be used for classification and also for validation of calculation models. In the test series, reference tests at normal temperature were included to obtain information (e.g. stiffness, strength) about the material tested in fire conditions. In addition, model-scale fire tests were performed to investigate the loss in stiffness resulting from fire exposure and the effect of different protection types. Loaded fire tests varied in the range of 41.8 min to 120 min, depending on the CLT structure, the level of load, and the type of protection. Data on temperature within specimens and residual cross-sections were collected. Charring rates evaluated from experimental results were comparable with values proposed by Eurocode for the design of timber structures. Conservative solutions were obtained by using simplified design methods and comparing their results to test results and results of advanced modelling. It was shown that the load-bearing performance of CLT may show abrupt changes due to its layered structure. It is strongly recommended that a minimum residual depth depending on the CLT structure should be required in order to ensure robust building products.

Place, publisher, year, edition, pages
2015. Vol. 51, no 6, p. 1341-1370
Keywords [en]
Cross-laminated timber, Fire tests, Reduced cross-section method, Wall member
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-6867DOI: 10.1007/s10694-015-0516-8Local ID: 29348OAI: oai:DiVA.org:ri-6867DiVA, id: diva2:964708
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2019-07-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text
By organisation
SP Hållbar Samhällsbyggnad
In the same journal
Fire technology
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 11 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8