Day-Ahead Predictions of Electricity Consumption in a Swedish Office Building from Weather, Occupancy, and Temporal data
KTH Royal Institute of Technology, Sweden.ORCID iD: 0000-0002-9860-4472
Uppsala University, Sweden.
KTH Royal Institute of Technology, Sweden.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.
2015 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 108, p. 279-290Article in journal (Refereed) Published
Abstract [en]

An important aspect of demand response (DR) is to make accurate predictions for the consumption in the short term, in order to have a benchmark load profile which can be compared with the load profile influenced by DR signals. In this paper, a data analysis approach to predict electricity consumption on load level in office buildings on a day-ahead basis is presented. The methodology is: (i) exploratory data analysis, (ii) produce linear models between the predictors (weather and occupancies) and the outcomes (appliance, ventilation, and cooling loads) in a step wise function, and (iii) use the models from (ii) to predict the consumption levels with day-ahead prognosis data on the predictors. The data has been collected from a Swedish office building floor. The results from (ii) show that occupancy is correlated with appliance load, and outdoor temperature and a temporal variable defining work hours are connected with ventilation and cooling load. It is concluded from the results in (iii) that the error rate decreases if fewer predictors are included in the predictions. This is because of the inherent forecast errors in the day-ahead prognosis data. The achieved error rates are comparable with similar prediction studies in related work

Place, publisher, year, edition, pages
2015. Vol. 108, p. 279-290
Keywords [en]
Office building electricity consumption, Load level, Building energy management system, HVAC, Exploratory data analysis, Prediction, Regression, Demand response
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-6865DOI: 10.1016/j.enbuild.2015.08.052Scopus ID: 2-s2.0-84943265845Local ID: 28275OAI: oai:DiVA.org:ri-6865DiVA, id: diva2:964706
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2020-12-01Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sandels, Claes

Search in DiVA

By author/editor
Sandels, Claes
By organisation
Klimatisering och installationsteknik
In the same journal
Energy and Buildings
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 66 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf