Comparison of Co–C Eutectic-Point Cells for Thermocouple Calibration Between SP and NMIJ
National Metrology Institute of Japan, Japan.
RISE, SP – Sveriges Tekniska Forskningsinstitut.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
2014 (English)In: International journal of thermophysics, ISSN 0195-928X, E-ISSN 1572-9567, Vol. 36, no 2-3, p. 399-412Article in journal (Refereed) Published
Abstract [en]

As recently reported, the metal–carbon eutectic points seem to be useful as practical reference points for calibrating thermocouples. The melting temperature of the cobalt–carbon eutectic point (Co–C, 1324◦C) is an ideal solution for a reference point being at approximately the middle between the freezing point of copper (1084.62◦C) and the melting point of palladium (1554.8◦C). In this study, a comparison of reference Co–C cells used for thermocouple calibration service was performed between the Technical Institute of Sweden (SP) and the National Metrology Institute of Japan (NMIJ) by means of two circulating Pt/Pd thermocouples and one circulating Co–C cell in order to investigate the reliability of thermocouple calibration at the Co–C eutectic point. The reference Co–C cell at SP was designed and constructed in the National Physical Laboratory (NPL), and provided to SP, while the reference Co–C cell at NMIJ as well as the circulating cell was designed and constructed at NMIJ. The melting temperature of the reference Co–C cells at SP and NMIJ were evaluated by using the calibrated radiation thermometers at NPL and NMIJ, respectively, prior to the circulation of the thermocouples and the cell between SP and NMIJ. The temperature difference between the reference cells of SP and NMIJ, as measured by means of the circulating thermocouples, was found to be within 0.33◦C, while that measured by means of the circulating cell was found to be within 0.22◦C. The temperature of reference cells at SP and NMIJ was found to agree within an expanded uncertainty (k=2) in spite of different temperature traceability chains. This means that the calibration of thermocouples at the Co–C eutectic point was sufficiently reliable.

Place, publisher, year, edition, pages
2014. Vol. 36, no 2-3, p. 399-412
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-6701DOI: 10.1007/s10765-014-1750-xScopus ID: 2-s2.0-84925515532Local ID: 23696OAI: oai:DiVA.org:ri-6701DiVA, id: diva2:964541
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2020-12-01Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus
By organisation
SP – Sveriges Tekniska ForskningsinstitutVolym, flöde, temperatur o densitet
In the same journal
International journal of thermophysics
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 34 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf