Intercomparison of lateral scales of scanning electron microscopes and atomic force microscopes in research institutes in Northern Europe
MIKES Centre for Metrology and Accreditation, Finland.
MIKES Centre for Metrology and Accreditation, Finland.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Massa, kraft, längd och tryck.ORCID iD: 0000-0001-5203-5465
Justervesenet, Norway.
Show others and affiliations
2014 (English)In: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, no 4, p. 44013-Article in journal (Refereed) Published
Abstract [en]

An intercomparison of lateral scales of scanning electron microscopes (SEM) and atomic force microscopes (AFM) in various research laboratories in Northern Europe was organized by the local national metrology institutes. In this paper are presented the results of the comparison, with also an example uncertainty budget for AFM grating pitch measurement. Grating samples (1D) were circulated among the participating laboratories. The participating laboratories were also asked about the calibration of their instruments. The accuracy of the uncertainty estimates seemed to vary largely between the laboratories, and for some laboratories the appropriateness of the calibration procedures could be considered. Several institutes (60% of all results in terms of En value) also had good comprehension of their measurement capability. The average difference from reference value was 6.7 and 10.0 nm for calibrated instruments and 20.6 and 39.9 nm for uncalibrated instruments for 300 nm and 700 nm gratings, respectively. The correlation of the results for both nominally 300 and 700 nm gratings shows that a simple scale factor calibration would have corrected a large part of the deviations from the reference values.

Place, publisher, year, edition, pages
2014. Vol. 25, no 4, p. 44013-
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-6685DOI: 10.1088/0957-0233/25/4/044013Scopus ID: 2-s2.0-84896778155Local ID: 23674OAI: oai:DiVA.org:ri-6685DiVA, id: diva2:964525
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2019-08-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Bergstrand, Sten

Search in DiVA

By author/editor
Bergstrand, Sten
By organisation
Massa, kraft, längd och tryck
In the same journal
Measurement science and technology
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 9 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8