System disruptions
We are currently experiencing disruptions on the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A novel method to evaluate fire test performance of water mist and water spray total compartment protection
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs ).ORCID iD: 0000-0002-6264-7307
2013 (English)In: Journal of Fire Protection Engineering, ISSN 1042-3915, E-ISSN 1532-172X, Vol. 23, no 4, p. 277-299Article in journal (Refereed) Published
Abstract [en]

Traditionally, the only parameter used to measure the performance of total compartment (i.e. total flooding) water mist or water spray systems during fire testing has been the time to extinguishment. However, the use of a single parameter has been criticized since it can result in poor system designs. This study evaluates additional parameters in order to improve the characterization of system performance. Two series of fire tests were conducted with a number of water mist and water spray fire protection systems: the former in a 500 m3 test compartment using three different systems; the latter in a 250 m3 compartment using four different systems. The heat release rate of the fire and the gas temperatures inside the test compartment were measured. Based on these measurements, the fire suppression capability of the systems, their temperature reduction capability and their ability to mix water vapor, water droplets and combustion gases within the compartment were determined. The tests revealed that the time to extinguishment varies several tens of percent under identical conditions. It was also observed that the relative performance of the systems was influenced by the size of the fire. The results obtained with the additional parameters were much more repeatable and consistent than using time to extinguishment alone. It is concluded that fairly simple and inexpensive measurements can improve current fire test procedures.

Place, publisher, year, edition, pages
2013. Vol. 23, no 4, p. 277-299
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-6596DOI: 10.1177/1042391513485954Scopus ID: 2-s2.0-84885141151Local ID: 23900OAI: oai:DiVA.org:ri-6596DiVA, id: diva2:964435
Available from: 2016-09-08 Created: 2016-09-08 Last updated: 2023-05-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Arvidson, Magnus

Search in DiVA

By author/editor
Arvidson, Magnus
By organisation
SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs )
In the same journal
Journal of Fire Protection Engineering
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 142 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf