P-marking of indoor environment and energy use - Considerations prior to certification of energy use
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.
2008 (English)Report (Refereed)
Abstract [en]

SP Technical Research Institute of Sweden's P-marking quality assurance scheme for buildings, products, services etc., now includes P-marking of the indoor environment and energy use performance of buildings. The rules for the system, which cover new buildings, renovation and existing buildings, are set out in SP’s Certification Rules no. SPCR 114E, specifying requirements in respect of both energy use and indoor environment management. Over the last ten years, SP has carried out considerable work in the field of the indoor environment, resulting in the development of a quality assurance system concentrating on achieving a high-quality indoor environment. This quality assurance system has been successfully applied to schools, offices and dwellings. However, the performance of a building is determined not only by a good indoor environment, but also by low impact on the external environment as a result of energy use in the building. In some cases, concentrating on either good indoor environment or energy efficiency may result in an adverse effect on the other aspect, and so the quality assurance system for indoor environments been extended with a section dealing with energy use. This document is a handbook for inspection of documentation concerning quality assurance of energy use (primary energy analysis, determination of energy targets, energy management systems etc.). It can also be helpful for the organisation that is applying for P-marking when drawing up checklists. The document concentrates on requirements for approved certification of energy use in connection with P-marking of indoor environments and energy use in existing buildings: it does not cover requirements for certification of indoor environments. It starts by describing targeting, aims and requirements for P-marking of energy use, followed by presentation of some examples of inspections of collected documentation. Key words: quality assurance, indoor environment, energy use, buildings

Place, publisher, year, edition, pages
2008.
Series
SP Rapport, ISSN 0284-5172 ; 2008:10
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-4811Local ID: 9037ISBN: 978-91-85829-24-8 (print)OAI: oai:DiVA.org:ri-4811DiVA: diva2:962449
Available from: 2016-09-07 Created: 2016-09-07Bibliographically approved

Open Access in DiVA

fulltext(463 kB)15 downloads
File information
File name FULLTEXT01.pdfFile size 463 kBChecksum SHA-512
354331bdf5b52ce3c55b2b84c5d4235f68191535c4f5cdc8084337c5d1127f7c1b6f5456e3a549bb2898ba3a39183905377caee5c66b773b606fd5f9a3d7fac8
Type fulltextMimetype application/pdf

By organisation
Klimatisering och installationsteknik
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 15 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 2 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.28.0