Strength properties of wood adhesives after exposure to fire. Nordtest project 1482-00
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Bygg och Mekanik.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Bygg och Mekanik.
2001 (English)Report (Refereed)
Abstract [en]

Nordtest and SP Swedish National Testing and Research Institute (SP) have financed a study to draft a common Nordic test method to classify wood adhesives for structural purposes according to strength properties after fire exposure. The study has been planned and carried out in cooperation between SP and Norwegian Institute of Wood Technology (NTI) with participation of Otto Graf Institute in Germany (FMPA). Glulam beams produced with six different adhesives have been exposed to fire. Temperature distribution during the fire exposure test, weight loss and charring rate have been determined. Shear strength of glulines and wood have been determined and delamination tests have been carried out on samples exposed to fire and samples not exposed to fire. Short term shear strength and creep rupture tests at elevated temperature have been carried out on samples with wood adhesives used in the test. Preliminary calculations of temperature distributions during fire in wooden members protected against direct fire exposure by gypsum board have been made. The results of the study on beams not protected by gypsum indicate that a wood adhesive that has shown favourable results in a creep rupture test at elevated temperature (80 °C) also will perform well during and after direct fire exposure. A static load test at elevated temperature can be used as an efficient and cheap method as an alternative to fire exposure tests of glued products for structural use. The results of the preliminary calculations on temperature distributions during fire exposure of gypsum protected smaller wood members indicate that under certain circumstances, the temperature can reach and stay at temperatures above 120 °C for a longer period of time. An additional test at higher temperature could be needed for adhesives intended for such structures.

Place, publisher, year, edition, pages
2001. , 30 p.
Series
SP Rapport, ISSN 0284-5172 ; 2001:35
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-4553Local ID: 621ISBN: 91-7848-883-4 (print)OAI: oai:DiVA.org:ri-4553DiVA: diva2:962191
Note
Pris: 150SEK. Beställes via BiblioteketBoras@sp.seAvailable from: 2016-09-07 Created: 2016-09-07Bibliographically approved

Open Access in DiVA

fulltext(707 kB)10 downloads
File information
File name FULLTEXT01.pdfFile size 707 kBChecksum SHA-512
82085aab4b09cebf7529b6afecc47ec5ea3f7fb888f5500abf7aa4e6f24cfb41d330ff4c914fbfaf722d33a146b60053444b9ebf0916190fb17f3be9b871b898
Type fulltextMimetype application/pdf

By organisation
SP Bygg och Mekanik
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 10 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 14 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.28.0