Two-way slabs: Experimental investigation of load redistributions in steel fibre reinforced concrete
2014 (English)In: Engineering structures, ISSN 0141-0296, E-ISSN 1873-7323, Vol. 80, 61-74 p.Article in journal (Refereed)
Abstract [en]

In the design of two-way reinforced concrete slabs, e.g. using the strip or yield line design method, the possibility of redistributing the load between different loading directions is used. The main aim of the present study was to investigate how fibres affect the structural behaviour such as the possibility for redistribution, crack patterns and load-carrying capacity. The investigation was conducted by means of experiments on two-way octagonal slabs, simply supported on four edges, centrically loaded with a point load. The slabs spanned 2.2m in both directions and the reinforcement amount was twice as large in one direction as in the other, in order to provoke uneven load distribution. Three slabs of each reinforcement configuration were produced and tested: conventionally reinforced slabs, steel fibre reinforced slabs and a combination of both reinforcement types. The reaction force on each supported edge was measured on five rollers per edge. A moderate fibre content (35kg/m3) of double hook-end steel fibres was used. The steel fibres affected the structural behaviour significantly by providing post-cracking ductility and by increasing the ultimate load-carrying capacity by approximately 20%. Most significant, the steel fibres influenced the load redistribution in such a way that more load could be transferred to supports in the weaker direction after cracking. Further, more evenly distributed support reactions were obtained in the slabs containing both reinforcement types compared to the case when only conventional reinforcement was used. The slabs reinforced by steel fibres alone did not experience any bending hardening; however, a considerable post-cracking ductility was observed. Furthermore, the work presented in this paper will provide results suitable for use in benchmarking numerical and analytical modelling methods for steel fibre reinforced concrete, as the experimental programme also included extensive testing of material properties.

Place, publisher, year, edition, pages
2014. Vol. 80, 61-74 p.
Keyword [en]
Concrete slab, Experimental investigation, Load distribution, Steel fibre reinforced concrete
National Category
Other Materials Engineering
Identifiers
URN: urn:nbn:se:ri:diva-2697Local ID: 4686OAI: oai:DiVA.org:ri-2697DiVA: diva2:960300
Available from: 2016-09-07 Created: 2016-09-07 Last updated: 2017-11-21Bibliographically approved

Open Access in DiVA

No full text

In the same journal
Engineering structures
Other Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 9 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.29.1