RoBound – Ro-ro space boundary fire protection – Fire integrity between ro-ro space and accommodation space
RISE Research Institutes of Sweden, Safety and Transport, Safety Research. (Fire Safe Transport)ORCID iD: 0000-0002-7874-2405
2021 (English)Report (Other academic)
Abstract [en]

The International Maritime Organization, through its correspondence group on fire safety, has underlined the need for more scientific studies regarding the performance of A-60 boundaries in case of a ro-ro space fire, especially to prevent fire spread to accommodation spaces. RISE has carried out the RoBound project in order to answer to this need. The goal of the project was to clarify the performance of “state-of-the-art” fire boundaries between ro-ro spaces and accommodation spaces or other ro-ro spaces, and to give recommendations on how sufficient fire containment is ensured.In order to obtain realistic exposure reached during a fire within a ro-ro space, simulations were performed using Computational Fluid Dynamics (Fire Dynamics Simulator).The first step was to model representative ro-ro spaces as well as representative cargo. Two representative ro-ro spaces were then defined: closed and open ro-ro spaces with open ends. Concerning the cargo, the ro-ro spaces were assumed fully loaded with trucks or fully loaded with cars. Moreover, two types of thermal insulation were chosen, A-60 and A-30. The highest temperature given for each simulated case was then compared with time-temperature curves for designing fire safety.Almost all comparisons showed that the hydrocarbon time-temperature curve fits better to the highest temperature reached in the simulations. The hydrocarbon time-temperature curve is more severe than the standard (cellulosic) time-temperature curve according to ISO 834, used for type approval of thermal insulation. Experimental tests were then carried out to observe the performance of A class insulation when exposed to the more representative hydrocarbon time-temperature curve in a cubic furnace. The fire insulations were mounted on steel plates with different thicknesses (5 mm, 6 mm and 12 mm).Tests results showed a significantly reduced fire integrity when exposed to the hydrocarbon time-temperature curve, meaning that it took less time to reach the maximum temperature elevations required by the FTP Code (140 °C for the average temperature elevation and 180 °C for the highest temperature elevation). The reduction was about 50%, depending on the thickness of the steel plate. These results apply for stone wool. Glass wool fire insulation was also used in the tests but it was deteriorated when exposed to the high heat exposure in accordance with the hydrocarbon time-temperature curve.

Place, publisher, year, edition, pages
2021. , p. 35
Series
RISE Rapport ; 2021:69
Keywords [en]
ro-ro space, ro-ro deck, SOLAS, guidance, open ro-ro space, closed ro-ro space, A class division, FTP Code, Thermal Insulation, ISO 834, time-temperature curve
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:ri:diva-54764ISBN: 978-91-89385-59-7 (electronic)OAI: oai:DiVA.org:ri-54764DiVA, id: diva2:1576817
Funder
Swedish Transport Administration, TRV 2019/96119The Swedish Mercantile Marine FoundationAvailable from: 2021-07-01 Created: 2021-07-01 Last updated: 2021-07-01Bibliographically approved

Open Access in DiVA

fulltext(3086 kB)200 downloads
File information
File name FULLTEXT01.pdfFile size 3086 kBChecksum SHA-512
ab24357ef91b947a06e79acddd54bbfccf7506346bd9c8322d20eec53596435432c14655af86ac241631fc915166bb3df16cc36d469845919760fa05a15eb67a
Type fulltextMimetype application/pdf

Authority records

Mindykowski, Pierrick

Search in DiVA

By author/editor
Mindykowski, Pierrick
By organisation
Safety Research
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 208 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 273 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf