Experimental study on the mechanical properties of fire exposed concrete
RISE Research Institutes of Sweden.
DTU Technical University of Denmark, Denmark.
DTU Technical University of Denmark, Denmark.
2021 (English)In: Safety Science, ISSN 0925-7535, E-ISSN 1879-1042, Vol. 142, article id 105357Article in journal (Refereed) Published
Abstract [en]

A number of fire-induced collapses of concrete buildings has been reported over the last decades, indicating the need of a better understanding of behaviour of concrete during fire events and of reassessing models recommended by currently used standards for structural fire safety design.This study investigates the mechanical properties of concrete exposed to elevated temperatures. After carrying out preliminary compression and temperature tests, ductility and strength of cylindrical concrete specimens at high temperature were measured in transient and non-transient tests. In transient tests, the specimens were preloaded to a certain stress level and heated up to failure. In non-transient tests, specimens were first heated up to a set temperature and then compressed until failure.The results are presented in terms of stress-strain relationships and critical temperatures. Such results are compared with different concrete models found in literature, as well as with the values recommended by the Eurocode (EN, 2004). The analysis of the strength degradation in non-transient tests indicated that strength values recommended by the Eurocode may not be conservative. Similar conclusions were drawn regarding the strain at peak stress, where the values suggested by Eurocode were found to be unrealistic from the design point of view. Based on the comparison of results obtained in transient and non-transient test, more conservative values of the strength were observed in transient tests. More tests are needed, in order to confirm these conclusions on larger data set. 

Place, publisher, year, edition, pages
Elsevier B.V. , 2021. Vol. 142, article id 105357
Keywords [en]
Compressive tests, Concrete in fire, Stress–strain curve, article, compression, critical temperature, experimental study, fire protection, high temperature, stress strain relationship
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:ri:diva-54482DOI: 10.1016/j.ssci.2021.105357Scopus ID: 2-s2.0-85107825989OAI: oai:DiVA.org:ri-54482DiVA, id: diva2:1570276
Note

Export Date: 21 June 2021; Article; CODEN: SSCIE; Correspondence Address: Zawadowska, A.; RISE Research Institutes of Sweden Safety and TransportSweden; email: olazawadowska@gmail.com

Available from: 2021-06-21 Created: 2021-06-21 Last updated: 2021-06-21Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus
By organisation
RISE Research Institutes of Sweden
In the same journal
Safety Science
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 24 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf