Key comparison EURAMET.PR-K2.a.2011-spectral responsivity in the range of 900 nm to 1600 nm
VSL, Netherlands.
VSL, Netherlands.
NPL, UK.
NPL, UK.
Show others and affiliations
2020 (English)In: Metrologia, ISSN 0026-1394, E-ISSN 1681-7575, Vol. 57, no 1 A, article id 02003Article in journal (Refereed) Published
Abstract [en]

The Euramet.PR-K2.a comparison on spectral responsivity for the wavelength range 900 nm to 1600 nm, as described in this report, was carried out to establish the degree of equivalence for the participating European laboratories with respect to the Key Comparison Reference Value (KCRV) of the CCPR-K2.a-2003 comparison. Seven laboratories, including pilot and link laboratory, participated. The comparison was piloted by VSL (Netherlands). Both VSL and NPL (UK) act as link laboratories to the CCPR-K2.a-2003 comparison. Most laboratories show a DoE within 1 % from the CCPR KCRV for almost the full wavelength range, with some slightly larger differences mostly above 1450 nm. One laboratory shows larger deviations, up to 3%. This report provides an overview of the comparison, a description of the characterization of the reference detectors, the data-analysis, participant results and their uncertainties and the degree of equivalence of participating laboratories with the CCPR KCRV. The full Technical Reports of the participants are included in the Appendix of the comparison report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). 

Place, publisher, year, edition, pages
Institute of Physics Publishing , 2020. Vol. 57, no 1 A, article id 02003
Keywords [en]
Uncertainty analysis, Degree of equivalence, Key comparison, Key comparison database, Key comparison reference values, Mutual recognition arrangements, Netherlands, Spectral responsivity, Wavelength ranges, Laboratories
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-48901DOI: 10.1088/0026-1394/57/1A/02003Scopus ID: 2-s2.0-85090590417OAI: oai:DiVA.org:ri-48901DiVA, id: diva2:1469802
Available from: 2020-09-22 Created: 2020-09-22 Last updated: 2023-05-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Andersson, Anne

Search in DiVA

By author/editor
Andersson, Anne
By organisation
Measurement Technology
In the same journal
Metrologia
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 50 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf